TY-FB7HD - Panasonic TV Service Manual (repair manual). Page 8

Read Panasonic TY-FB7HD Service Manual online

1.1.2 Leakage Current Hot Check (See 
Figure 
1
 .) 
TOP
 
PREVIOUS
 
NEXT
 
1.  Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this 
check.
2.  Connect a 1.5k
, 10 watts resistor, in parallel with a 0.15
μF capacitors, between each 
exposed metallic part on the set and a good earth ground such as a water pipe, as shown in 
Figure 1
 .
3.  Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across 
the resistor.
4.  Check each exposed metallic part, and measure the voltage at each point.
5.  Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6.  The potential at any point should not exceed 0.75 volts RMS. A leakage current tester 
(Simpson Model 229 or equivalent) may be used to make the hot checks, leakage current must 
not exceed 1/2 milli amp. In case a measurement is outsideof the limits specified, there is a 
possibility of a shock hazard, and the equipment should be repaired and rechecked before it is 
returned to the customer.
TOP
 
PREVIOUS
 
NEXT
 
Page of 51