Power LED blinking timing chart
1. Subject
Information of LED Flashing timing chart.
2. Contents
When abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the
defective block can be identified by number of blinking of the Power LED on the front panel of the unit.
defective block can be identified by number of blinking of the Power LED on the front panel of the unit.
Blinking
times
Blinking timing
Contents
Check point
1
BL_SOS
A BOARD
Tcon-UNIT on panel
3
SOS
A BOARD
4
SUB12V_SENSE_SOS
A BOARD
7
SUB3.3V_SENSE_SOS
A BOARD
9
SOUND_SOS
A BOARD
P BOARD
P BOARD
10
LP1 IC
A-BOARD
Tcon-UNIT on panel
12
BE(LDA3)SOS
A BOARD
13
EMERGENCY
A BOARD
14
IROM_SOS A-BOARD
No Light