TX-51P100X, TX-51P100H, TX-51P100HL, TX-51P100HQ, TX-51P100HZ - Panasonic TV Service Manual (repair manual)

tx-51p100x, tx-51p100h, tx-51p100hl, tx-51p100hq, tx-51p100hz service manual
Model
TX-51P100X TX-51P100H TX-51P100HL TX-51P100HQ TX-51P100HZ
Pages
108
Size
23.36 MB
Type
PDF
Document
Service Manual
Brand
Device
TV / E3D
File
tx-51p100x-tx-51p100h-tx-51p100hl-tx-51p100hq-tx-5.pdf
Date

Read Panasonic TX-51P100X / TX-51P100H / TX-51P100HL / TX-51P100HQ / TX-51P100HZ Service Manual online

Screen Size:
Diagonal:
1296 mm
Height:
780 mm
Width:
1037 mm
Projection Tube:
TVVAB10EHV (B-ASSY)
TVVAG10EHV (G-ASSY)
TVVAR10EHV (R-ASSY)
90
°
 deflection
High Voltage:
34.5 ± 0.5 kV at zero beam current
Audio Output:
Internal Speaker
24 W (10% THD) 
Impedance 8
Video/Audio Terminals:
AV1, 2, 3, 4 IN Video 
1 Vp-p 75
S-Video
Y: 1.0 Vp-p 75
C: 0.3Vp-p 75
Audio 
Approx. 0.5V 47k
Monitor OUT
Video 
1Vp-p 75
Audio 
Approx. 0.5V 1k
Dimensions:
Height:
1371 mm
Width:
1095 mm
Depth:
500 mm
Mass:
60.0 kg (Net)
Accessories Supplied:
Remote Controller x 1
“R6” Battery x 2
Design and Specifications are subject to change without notice.
Mass and dimensions shown are aproximate.
Specifications
Power Source:
TX-51P100H/H L /H Q /H Z :AC 220V-240V, 50/60Hz
TX-51P100X:
AC 110V-240V, 50/60Hz
Power Consumption:
TX-51P100H/H L /H Q /H Z :265W
TX-51P100X:
270W
0.7W (Stand-by condition)
Aerial Impedance:
75
 unbalanced, Coaxial type
Tuning System:
21 Systems
Frequency Synthesizer
Auto Search
100(Position)/125(Direct)
Receiving Channels:
2-12
(PAL/ SECAM - B, K1)
0-12
(PAL-B AUST.)
1-9
(PAL-B N.Z.)
1-12
(PAL/SECAM-D)
1-12
(NTSC-M JAPAN)
2-13
(NTSC-M U.S.A.)
21-69
(PAL-G, H, I)
21-69
(SECAM-G, K, K1)
28-69
(PAL-B AUST.)
13-57
(PAL-D, K)
13-62
(NTSC-M Japan)
14-69
(NTSC-M U.S.A.)
CATV
S1-S20
(OSCAR)
S21-S41
(HYPER)
1-125
(U.S.A. CATV)
5A, 9A
(AUST.)
Z1-Z37
(CHINA)
C13-C49
(JAPAN)
Intermediate Frequency:
Video
38.0 MHz
Sound
31.5 MHz (D, K)/32.0 MHz (I)
32.5 MHz (B, G)/33.5 MHz (M)
Colour
33.57 MHz (PAL)/33.6 MHz (SECAM)
33.75 MHz (SECAM)/34.42 MHz (NTSC)
Receiving Stereo sound system:
NICAM B/G, NICAM I,
NICAM D, A2 (German)
ã
ORDER NO.ITD9909030C3
                                                                                                             
Video Projection System
TX-51P100X
TX-51P100H
TX-51P100H L
TX-51P100H Q
TX-51P100H Z
E3D Chassis
Suffix at the end of the Model No.
(for example: L , Q , Z etc.) 
is indicated only in the
Serial Number label at Rear Cover
and Chassis.
Specifications
Power Source:
TX-51P100H/H L /H Q /H Z :AC 220V-240V, 50/60Hz
TX-51P100X:
AC 110V-240V, 50/60Hz
Power Consumption:
TX-51P100H/H L /H Q /H Z :265W
TX-51P100X:
270W
0.7W (Stand-by condition)
Aerial Impedance:
75
 unbalanced, Coaxial type
Tuning System:
21 Systems
Frequency Synthesizer
Auto Search
100(Position)/125(Direct)
Receiving Channels:
2-12
(PAL/ SECAM - B, K1)
0-12
(PAL-B AUST.)
1-9
(PAL-B N.Z.)
1-12
(PAL/SECAM-D)
1-12
(NTSC-M JAPAN)
2-13
(NTSC-M U.S.A.)
21-69
(PAL-G, H, I)
21-69
(SECAM-G, K, K1)
28-69
(PAL-B AUST.)
13-57
(PAL-D, K)
13-62
(NTSC-M Japan)
14-69
(NTSC-M U.S.A.)
CATV
S1-S20
(OSCAR)
S21-S41
(HYPER)
1-125
(U.S.A. CATV)
5A, 9A
(AUST.)
Z1-Z37
(CHINA)
C13-C49
(JAPAN)
Intermediate Frequency:
Video
38.0 MHz
Sound
31.5 MHz (D, K)/32.0 MHz (I)
32.5 MHz (B, G)/33.5 MHz (M)
Colour
33.57 MHz (PAL)/33.6 MHz (SECAM)
33.75 MHz (SECAM)/34.42 MHz (NTSC)
Receiving Stereo sound system:
NICAM B/G, NICAM I,
NICAM D, A2 (German)
   
- 2 -
Contents
 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   Cover
 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3
 Chassis Boards Layout  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4
 Disassembly for Service  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
 Service Hints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8
 CRT Set up  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12
 Special Servicing Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16
 Market Mode Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  17
 Service Adjustment Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20
 Location of Lead Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  31
 Conductor Views. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  35
 Block Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  51
 Schematic Diagrams  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  54
 Parts Location & Mechanical Replacement Parts List  . . . . . . . . . . . . . . . . .  78
 Replacement Parts List  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  80
 !"#
- 3 -
Safety Precautions
General Guide Lines
1. It is advisable to insert an isolation transformer in
the AC supply before servicing a hot chassis.
2. When servicing, observe the original lead dress,
especially the lead dress in the high voltage cir-
cuits.
If a short circuit is found, replace all parts which
have been overheated or damaged by the short
circuit.
3. After servicing, see to it that all the protective
devices such as insulation barriers, insulation
papers, shields, and isolation R-C combinations,
are properly installed.
4. When the receiver is not to be used for a long
period of time, unplug the power cord from the AC
outlet.
5. Potential, as high as 34.5kV, is present when this
monitor is in operation. Operation of the Projection
Monitor without the rear cover involves the danger
of a shock hazard from the power supply. Servicing
should not be attempted by anyone who is not
thoroughly familiar with the precautions necessary
when working on high voltage equipment.  Always
discharge the anode of the projection tube to the
Projection Monitor chassis before handling the
tube.
6. After servicing make the following leakage current 
checks to prevent the customer from being
exposed to shock hazards.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper
between the two prongs on the plug.
2. Turn on the Projection Monitor’s power switch.
3. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed
metallic cabinet part on the projection monitor,
such as screw heads, connectors, control shafts,
etc. When the exposed metallic part has a return
path to the chassis, the reading should be between
4 M
 and 20 M
.
When the exposed metal does not have a return
path to the chassis, the reading must be 
.
Leakage Current Hot Check (See Fig.1)
1. Plug the AC cord directly into the AC outlet. Do not
use an isolation transformer for this check.
2. Connect a 2k
, 10W resistor, in series with an
exposed metallic part on the projection monitor
and an earth such as a water pipe.
3. Use an AC voltmeter, with high impedance type, to
measure the potential across the resistor.
4. Check each exposed metallic part, and measure
the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat
each of the above measurements.
6. The potential at any point should not exceed 1.0V
rms. In case a measurement is outside of the limits
specified, there is a possibility of a shock hazard,
and the projection monitor should be repaired and
rechecked before it is returned to the customer.
X-Radiation
Warning :
1. The potential sources of X-Radiation in projection
monitor are the High Voltage section and the pro-
jection tube.
2. When using a projection tube test jig for service,
ensure that jig is capable of handling 32.5kV with-
out causing X-Radiation.
Note: It is important use an accurate periodically cali-
brated high voltage meter.
1. Set the brightness to minimum.
2. Set the service switch to the service position.
3. Measure the High Voltage. The meter reading
should indicate 34.5 ( ± 0.5 ) kV. If the meter indi-
cation is out of tolerance, immediate service and
correction is required to prevent the possibility of
premature component failure.
4. To prevent an X-Radiation possibility, it is essential
to use the specified projection tube.
Hot-Check Circuit
Fig. 1
AC Voltmeter
To
Instrument's
Exposed
Metallic Parts
2k
, 10W
Water Pipe
( Earth )
 !"#
- 4 -
Chassis Board Layout
P
D
FBT
MPU
E
A
G
H
B2
DG
CF
LB
LG
LR
SB
SG
SR
DC
CP
W
T
F
TNR
Board-Name
Function
A-Board
Main
D-Board
Main Power
P-Board
Line Filter
G-Board
Control Panel
E-Board 
Horizontal Deflection, High Voltage
F-Board
Vertical Deflection
CP-Board
Converter Output
DC-Board
Digital Converter
W-Board White 
Balance
LR-Board
CRT Drive (R)
LG-Board
CRT Drive (G)
LB-Board
CRT Drive (B)
SG-Board
VM Output (G)
SR-Board
VM Output (R)
SB-Board
VM Output (B)
DG1-Board
Digital Core
H-Board
Rear terminal
T-Board
Text
B2-Board
VIF/SIF
CF-Board
Interface correction
 !"#
Page of 108
Display

Download Panasonic TX-51P100X / TX-51P100H / TX-51P100HL / TX-51P100HQ / TX-51P100HZ Service Manual (Repair Manual)

Here you can read online and download Panasonic TX-51P100X / TX-51P100H / TX-51P100HL / TX-51P100HQ / TX-51P100HZ Service Manual in PDF. TX-51P100X / TX-51P100H / TX-51P100HL / TX-51P100HQ / TX-51P100HZ service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic TX-51P100X / TX-51P100H / TX-51P100HL / TX-51P100HQ / TX-51P100HZ TV. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.