TX-32PL1 - Panasonic TV Service Manual (repair manual). Page 4

Read Panasonic TX-32PL1 Service Manual online

ADJUSTMENT PROCEDURE
Item / Preparation
Adjustments
+B SET-UP
1. Receive 
Greyscale 
signal.
2.  Set the controls :-
Brightness
Minimum
Contrast
Minimum
Volume
Minimum
1.  Set the +B voltage up as follows:-
Adjust R811 so that B2 shows 148V±1V.
2.  Confirm the following voltages.
B9
5
±
0,25V B10
5
±
0,25V
B5
12
±
0,5V
B11
33
±
1,5V
B4
15
±
1V
B7
8
±
0,5V
B12 26
±
2V
B8
6
±
1V
B3
36
±
1,5V
B13
13
±
1V
B1
205
±
10V
B14
14
±
1V
CUT OFF / Ug2 Test
1. Receive 
Greyscale 
signal.
2.  Degauss the tube externally.
3.  Set the TV into Service Mode 1.
4.  Select Cut off mode.
To adjust Cutoff connect an oscilloscope to the Blue
cathode. Press "STR" and adjust "cutoff" value using the
"Yellow" and "Blue" buttons until the black level is 160V±5V,
press "STR" to store the value. Remove the oscilloscope.
Select Ug2 adjustment and adjust the screen VR until the
display shows "O.K."
FACTORY SETTINGS
To return customer settings to factory settings and clear owner ID of all information input by the customer , enter Self-Check
Mode. Press the down (-/v) button on the customer controls at the front of the TV set , at the same time pressing the
STATUS button 
 on the remote control. To exit Self Check , switch off the TV set at the power button.
NOTE: Self Check should only be used when refurbishing the TV set and not during normal repair work .
If the CCU ports have been checked and found to be incorrect or not located then " - - " will appear in place of "O.K.".
4
If the CCU ports have been checked and found to be incorrect or not located then " - - " will appear in place of "O.K.".
4
            TX- 32PL1
OPTION1
00
OPTION2
A1 
OPTION3
82
OPTION4
60 
OPTION5
B1 
OPTION6
E9
VDP
O.K.
TUN
O.K.
E2
O.K.
MSP
O.K.
PCB
O.K.
CAB
O.K.
DPL
 -  -
SUM
****   FACTORY USE 
   ONLY
Page of 38
Display