 ADJUSTMENT PROCEDURE
Item / Preparation
Adjustments
+B SET-UP
1.  Receive a Window pattern.
2.  Set the controls :
Brightness
Minimum
Contrast
Minimum
Volume
Minimum
Confirm the following voltages:
TPD1
205
± 10V
TPD11
5    
± 0,5V
TPD2
137
± 2V
TPD12
3,3
± 0,1V
TPD3
42
± 2V
TPD13
2,5
± 0,1V
TPD5
42
± 2V
TPD14
3,3     ± 0,1V
TPD6
12,5
± 1V
TPD15
5    
± 0,5V
TPD7
-12,5 ± 1V
TPD16
5
± 0,5V
TPD8
30,5
± 1V
TPG3
7,5
± 0,5V
TPD9
9
±  1V
TPG5
300
± 10V
TPD10
8
± 0,5V
CUT OFF / Ug2 Test
1. Receive a Window pattern.
2. Normalize the TV set.
3. Set brightness: minimum.
To adjust Cutoff connect an oscilloscope to the Blue cathode. Adjust
the screen VR until the black level is 170V +0V/-5V. 
SELF CHECK
Self-check is used to automatically check the bus lines and hexadecimal code of the TV set.To enter Self-Check mode, press
the STATUS         button on the remote control and at the same time press the down (-/v) button on the customer controls at
the front the TV set. To exit Self Check, switch off the TV set at the power button.
If the CCU ports have been checked and found to be incorrect or not located then " - - " will appear in place of "O.K.".
4
E2
O.K.
DDP
O.K.
VSP
O.K.
AVSW
O.K.
TUN
O.K.
MSP
O.K.
DPL
---
MAS
---
SUM
****
 TX-29PS10D
TX-29PS10F
TX-29PS10D/B
TX-29PS10P
OPTION 1
0F
0F
OPTION 2
00
00
OPTION 3
A0
A0
OPTION 4
11
11
OPTION 5
00
00
OPTION 6
24
24
OPTION 7
7F
7F
OPTION 8
D0
50
OPTION 9
00
00
OPTION 10
80
80
OPTION 11
09
09
OPTION 12
00
00
OPTION 13
08
08
CHECK
C4
44
Black Level
170V+0V/-5V
GND
Page of 37