Read Panasonic TX-28PL10D / TX-28PL10F Service Manual online
ADJUSTMENT PROCEDURE
Item/Preparation
Adjustments
+B SET-UP
1. Receive a Greyscale signal.
2. Set
2. Set
the
controls:-
Brightness:
Minimum
Contrast:
Minimum
Volume:
Minimum
1. Confirm the following voltages.
B2
148 ± 2V
B9
5
± 0,25V
B10
5
± 0,25V
B5
12
± 0,5V
B11
33
± 1,5V
B4
15
± 1V
B7
8
± 0,5V
B12
26
± 2V
B8
7
± 1V
B3
36
± 1,5V
B13
16
± 1V
B1
205 ± 10V
B14
-14 ± 1V
Cut-Off / Ug2 Test
1. Receive a Greyscale signal.
2. Degauss the tube externally.
3. Set the TV into Service Mode 1.
4. Select Cutoff mode.
2. Degauss the tube externally.
3. Set the TV into Service Mode 1.
4. Select Cutoff mode.
Connect an oscilloscope to the Blue cathode, adjust
"Screen" until the black level is 155V±3V. Remove the
oscilloscope.
"Screen" until the black level is 155V±3V. Remove the
oscilloscope.
ABGLEICH
Vorbereitungen
Abgleich
+B - Abgleich
1. Testbild
empfangen.
Helligkeit auf:
Minimum
Kontrast auf:
Minimum
Lautstärke:
Minimum
1. Folgende Spannungen sind zu überprüfen.
B2
148 ± 2V
B9
5
± 0,25V
B10
5
± 0,25V
B5
12
± 0,5V
B11
33
± 1,5V
B4
15
± 1V
B7
8
± 0,5V
B12
26
± 2V
B8
7
± 1V
B3
36
± 1,5V
B13
16
± 1V
B1
205 ± 10V
B14
-14 ± 1V
Cut-Off / Ug2 Test
1. Testbild
empfangen.
2. Bildröhre
entmagnetisieren.
3. Service-Mode 1 anwählen.
4. Im Service-Mode den Abgleichpunkt Cutoff DC-Mode
4. Im Service-Mode den Abgleichpunkt Cutoff DC-Mode
wählen.
Das Oszilloskop an blaue Kathode anschließen, den
Wert „SCREEN“ so einstellen, dass das schwarze
Niveau 155
Wert „SCREEN“ so einstellen, dass das schwarze
Niveau 155
± 3V beträgt. Das Oszilloskop abschalten.
7