ADJUSTMENT PROCEDURE
Item / Preparation
Adjustments
+B SET-UP
1. Receive 
Greyscale 
signal.
2.  Set the controls :-
Brightness
Minimum
Contrast
Minimum
Volume
Minimum
1.  Set the +B voltage up as follows:-
Adjust R811 so that B2 shows 148V±1V.
2.  Confirm the following voltages.
B9
5
±
0,25V B10
5
±
0,25V
B5
12
±
0,5V
B11
33
±
1,5V
B4
15
±
1V
B7
8
±
0,5V
B12 26
±
2V
B8
6
±
1V
B3
36
±
1,5V
B13
13
±
1V
B1
205
±
10V
B14
14
±
1V
CUT OFF / Ug2 Test
1. Receive 
Greyscale 
signal.
2.  Degauss the tube externally.
3.  Set the TV into Service Mode 1.
4.  Select Cut off mode.
To adjust Cutoff connect an oscilloscope to the Blue
cathode. Press "STR" and adjust "cutoff" value using the
"Yellow" and "Blue" buttons until the black level is 160V±5V,
press "STR" to store the value. Remove the oscilloscope.
Select Ug2 adjustment and adjust the screen VR until the
display shows "O.K."
FACTORY SETTINGS
Self-check is used to automatically check the bus lines and hexadecimal code of the TV set. To get in to Self-Check mode
press the down (-/v) button on the customer controls at the front of the TV set, at the same time pressing the STATUS button
on the remote control.
If the CCU ports have been checked and found to be incorrect or not located then " - - " will appear in place of "O.K.".
4
TX- 28PG45
OPTION1
0D
OPTION8
41
OPTION2
00 OPTION9
81
OPTION3
10
OPTION10
80
OPTION4
10 OPTION11
1B
OPTION5
00 OPTION12
28
OPTION6
50 OPTION13
FA
OPTION7
00 CHECK
FC
TUN1
O.K.
TUN2
-- --
DAC1
O.K.
MSP
O.K.
DOLBY
O.K.
CODEC
O.K.
DAC2
O.K.
DAC3
O.K.
MEM
O.K.
GC1
O.K.
GC2
-- --
VDU
O.K.
CIP
O.K.
RGB
O.K.
AVSW
O.K.
 To exit Self Check, switch off the TV set at the power button.