Read Panasonic TX-28LB10C / TX-28LB10S Service Manual online
ADJUSTMENT PROCEDURE
Item/Preparation
Adjustments
+B SET-UP
1. Receive a Greyscale signal.
2. Set the controls:
2. Set the controls:
Brightness:
Minimum
Contrast:
Minimum
Volume:
Minimum
Confirm the following voltages.
B2
148 ± 2V
B10
5,25 ± 0,25V
B9
5
± 0,25V
B11
33
± 1,5V
B5
12
± 0,5V
B7
8
± 0,5V
B4
16
± 1V
B8
6
± 1V
B12
26
± 2V
B13
16,5 ± 1V
B3
36
± 1,5V
B14
-10 ± 1V
B1
205 ± 10V
Cut-Off / Ug2 Test
1. Receive a Greyscale signal.
2. Degauss the tube externally.
3. Set the TV into Service Mode 1.
4. Select Cutoff mode.
2. Degauss the tube externally.
3. Set the TV into Service Mode 1.
4. Select Cutoff mode.
Connect an oscilloscope to the Blue cathode, adjust
"Screen" until the black level is 155V±3V. Remove the
oscilloscope.
"Screen" until the black level is 155V±3V. Remove the
oscilloscope.
ABGLEICH
Vorbereitungen
Abgleich
+B - Abgleich
1. Testbild empfangen.
2. Helligkeit auf:
2. Helligkeit auf:
Minimum
Kontrast auf:
Minimum
Lautstärke:
Minimum
Folgende Spannungen sind zu überprüfen.
B2
B2
148 ± 2V
B10
5,25 ± 0,25V
B9
5
± 0,25V
B11
33
± 1,5V
B5
12
± 0,5V
B7
8
± 0,5V
B4
16
± 1V
B8
6
± 1V
B12
26
± 2V
B13
16,5 ± 1V
B3
36
± 1,5V
B14
-10 ± 1V
B1
205 ± 10V
Cut-Off / Ug2 Test
1. Testbild empfangen.
2. Bildröhre entmagnetisieren.
3. Service-Mode 1 anwählen.
4. Im Service-Mode den Abgleichpunkt Cutoff DC-Mode
2. Bildröhre entmagnetisieren.
3. Service-Mode 1 anwählen.
4. Im Service-Mode den Abgleichpunkt Cutoff DC-Mode
wählen.
Das Oszilloskop an blaue Kathode anschließen, den
Wert „SCREEN“ so einstellen, dass das schwarze
Niveau 155V
Wert „SCREEN“ so einstellen, dass das schwarze
Niveau 155V
± 3V beträgt. Das Oszilloskop abschalten.
7