SELF CHECK
1.  Self-check is used to automatically check the bus lines and hexadecimal code of the TV set.
2.  To get into the Self-Check  mode press the down
(-/v) button on the customer controls at the front of the set, at the same time pressing the STATUS button on the remote
control, and the screen will show :-
ADJUSTMENT PROCEDURE
Item/Preparation
Adjustments
+B SET-UP
1. Receive 
Greyscale 
signal.
2.  Set the controls:-
Brightness
Minimum
Contrast
Minimum
Volume
Minimum
1.  Set the +B voltage up as follows:-
Adjust R811 so that B2 shows 148V ± 1V
Confirm the following voltages.
B9
5
±
0,25V
B10
5
±
0,25V
B5
12
±
0,5V
B11
33
±
1,5V
B4
16
±
1V
B7
8
±
0,5V
B12
26
±
1V
B8
5,5
±
0,5V
B3
35
±
1V
B13
15
±
1V
B1
200
±
10V
B14
-15
±
1V
Cut-Off / Ug2 Test
1. Receive 
Greyscale 
signal.
2.  Degauss the tube externally.
3.  Set the TV into Service Mode 1.
4.  Select Cutoff mode.
To adjust Cutoff connect an oscilloscope to the Blue
cathode. Press "STR" and adjust "cutoff" value using the
"Yellow" and "Blue" buttons until the black level is
160V ± 5V, press "STR" to store the value. Remove the
oscilloscope.
Select Ug2 adjustment and adjust the screen VR until the
display shows "O.K."
If the CCU ports have been checked and found to be incorrect or not located then " - - " will appear in place of "O.K.".
VDP
O.K.
TUN
O.K.
E2
O.K.
MSP
O.K.
DPL
- -
PCB
O.K.
Cab
O.K.
Sum
Factory use
only
TX-25AS1C/M
OPTION1 3D
OPTION2 1C
OPTION3 0D
OPTION4 40
OPTION5 FF
OPTION6 E3
TX-25AS1D/M
OPTION1 39
OPTION2 1C
OPTION3 0F
OPTION4 40
OPTION5 FF
OPTION6 E5
TX-25AS1F/M
OPTION1 39
OPTION2 1C
OPTION3 0F
OPTION4 40
OPTION5 FD
OPTION6 E5
5