Read Panasonic TH-42LF5E / TH-47LF5E Service Manual online
Adjustment Method
RGB white balance adjustment
Instrument Name
Connect to
Remarks
INTERNAL PATTERN – 100% WHITE
Color analyzer
( Minolta CA-210 or equivalent )
( Minolta CA-210 or equivalent )
Panel surface
Picture menu: STANDARD
User setting: Normal
except PICTURE: max 30
User setting: Normal
except PICTURE: max 30
Procedure
Remarks
[Conditions]
Make sure the front panel to be used on the final set is fitted.
Center position
[Adjustment]
1. Set COMPONENT / RGB-IN SELECT to COMPONENT
2. Select the IIC mode “LCD Drive Adj.” item.
3. Check that the color temperature is “MID”.
4. Output a white balance pattern.
5. Touch the signal receiver of color analyzer to the highlight window’s center.
6. Fix G drive at 30h and adjust B drive and R drive so x, y become the “Colour
2. Select the IIC mode “LCD Drive Adj.” item.
3. Check that the color temperature is “MID”.
4. Output a white balance pattern.
5. Touch the signal receiver of color analyzer to the highlight window’s center.
6. Fix G drive at 30h and adjust B drive and R drive so x, y become the “Colour
temperature NORMAL(Mid) in the below table.
7. At least fix one of the RGB’s drive data at 30h and adjust the others drive so x/y
(The highest RGB’s drive value is 30h).
Table W/B adjustment values
Color Temperature
x
y
NORMAL(Mid) 0.288
0.296
Adjustment target
Hi-light. X ± 0.005 y ± 0.005
Hi-light is target of the number at drive adjustment in the hi–light windows.
Therefore, it is not target of the hi-light number at after adjustment white balance.
Note :
Hi-light. X ± 0.005 y ± 0.005
Hi-light is target of the number at drive adjustment in the hi–light windows.
Therefore, it is not target of the hi-light number at after adjustment white balance.
Note :
Internal signal: STANDARD
Aspect: Full
Picture setting: Standard
Backlight: 100(Default)
“7“ key: color temperature select
Aspect: Full
Picture setting: Standard
Backlight: 100(Default)
“7“ key: color temperature select
Color temperature – Normal
(Mid.)
(Mid.)
Let the panel stand for more than 3
hours at more than 20
C.
Basically perform adjustment in the
ambient environment of room
temperature more than 20
ambient environment of room
temperature more than 20
C.
The aging time is more than20 min
at above room temperature.
at above room temperature.
Change DRIVE(R,G,B) by UP/DOWN buttons on the remote control
+
-
Change Value Register by VOL+/- buttons on the remote control
19
Click on the first or last page to see other TH-42LF5E / TH-47LF5E service manuals if exist.