1 SAFETY PRECAUTIONS
1.1. GENERAL GUIDELINES
 1. IMPORTANT SAFETY NOTICE
There are special components used in this equipment
which are important for safety. These parts are marked by
in the Schematic Diagrams, Circuit Board Layout,
Exploded Views and Replacement Parts List. It is essential
that
these
critical
parts
should
be
replaced
with
manufacturer’s specified parts to prevent shock, fire, or
other hazards. Do not modify the original design without
permission of manufacturer.
 2. An Isolation Transformer should always be used during the
servicing of Combination LCD TV/DVD-RAM whose chassis
is not isolated from the AC power line. Use a transformer of
adequate power rating as this protects the technician from
accidents resulting in personal injury from electrical shocks.
It will also protect Combination LCD TV/DVD-RAM from
being damaged by accidental shorting that may occur
during servicing.
 3. When servicing, observe the original lead dress, especially
the lead dress in the high voltage circuits. If a short circuit is
found, replace all parts which have been overheated or
damaged by the short circuit.
 4. After servicing, see to it that all the protective devices such
as insulation barriers, insulation papers, shield,
and
isolation R-C combinations are properly installed.
 5. When the TV set is not used for a long period of time,
unplug the power cord from the AC outlet.
 6. After servicing make the following leakage current checks to
prevent the customer from being exposed to shock
hazards.
1.2. LEAKAGE CURRENT COLD
CHECK
 1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
 2. For physically operated power switches, turn power on.
Otherwise skip step 2.
 3. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the receiver, such as screwheads, connectors, etc.
When the exposed metallic part has a return path to the
chassis, the reading should be between 1 M
and 8.5 M
.
When the exposed metal does not have a return path to the
chassis, the reading must be infinity.
1.3. LEAKAGE CURRENT HOT
CHECK
 1. Plug the AC cord directly into the AC outlet.
Do not use a isolation transformer for this check.
 2. Connect a 1.5 k
, 10 W resistor, in parallel with a 0.15 µF
capacitor, between each exposed metallic part on the set
and a good earth ground, as shown in Figure 1.
 3. Use an AC voltmeter, with 1 k
/V or more sensitivity, to
measure the potential across the resistor.
 4. Check each exposed metallic part, and measure the
voltage at each point.
 5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
 6. The potential at any point should not exceed 0.75 V RMS.
A leakage current tester (Simpson Model 229 equivalent)
may be used to make the hot checks. Leakage current must
not exceed 1/2 mA. In case a measurement is outside of
the limits specified, there is a possibility of shock hazard,
and the receiver should be repaired and rechecked before
it is returned to the customer.
Figure 1