Read Panasonic CT-34WDM60 Service Manual online
- 8 -
Inspection procedure using the self-check function for the power supply system
Caution items at the time of inspection
•
Always pull the plug of the AC code before performing a continuity check.
•
When solder has been removed or a connector has been pulled, please restore the original condition after each inspection.
•
When the tester has been set to
Ω
a voltage with the opposite polarity of the voltage impressed when the tester is used as a
voltmeter is put out from the tester, and for inspection of a load short-circuit, connect the tester rod on the plus side (red) to
earth and the tester rod on the minus side (black) to the power supply line.
earth and the tester rod on the minus side (black) to the power supply line.
•
Generally, a value of 10
Ω
or less can be considered as a load short-circuit.
The main power/video reception LED does not light.
W
Load
BLACK
RED
The main power/video reception
LED does not light even when
the main power switch is set to ON.
LED does not light even when
the main power switch is set to ON.
Is the fuse F801 blown?
Perform short-circuit inspection
for the AC 120 V line
(T801, D841 to D844, C842, etc.).
Exchange the fuse F801.
for the AC 120 V line
(T801, D841 to D844, C842, etc.).
Exchange the fuse F801.
Is a voltage of 10 V
supplied to pin 1 of the
connector E15?
supplied to pin 1 of the
connector E15?
Is a voltage of 5 V
supplied to pin 4
of IC3111?
supplied to pin 4
of IC3111?
Exchange U-Module
Unsolder pin 1
of the connector E15
and check if a voltage of
10 V is supplied to pin 1
of the connector
D15.
D841 to D844, C842
short-circuit inspection,
exchange
short-circuit inspection,
exchange
IC3111, C3124 short-circuit
inspection, exchange
inspection, exchange
IC3111 open inspection, C3071,
C3098 short-circuit inspection,
exchange
C3098 short-circuit inspection,
exchange
Yes
Yes
Yes
No
No
No
No
Yes
& !"#$