CT-34WDM60 - Panasonic TV Service Manual (repair manual). Page 8

Read Panasonic CT-34WDM60 Service Manual online

- 8 -
Inspection procedure using the self-check function for the power supply system
Caution items at the time of inspection
Always pull the plug of the AC code before performing a continuity check.
When solder has been removed or a connector has been pulled, please restore the original condition after each inspection.
When the tester has been set to 
 a voltage with the opposite polarity of the voltage impressed when the tester is used as a
voltmeter is put out from the tester, and for inspection of a load short-circuit, connect the tester rod on the plus side (red) to
earth and the tester rod on the minus side (black) to the power supply line.
Generally, a value of 10 
 or less can be considered as a load short-circuit.
The main power/video reception LED does not light.
W
Load
BLACK
RED
The main power/video reception
LED does not light even when
the main power switch is set to ON.
Is the fuse F801 blown?
Perform short-circuit inspection
for the AC 120 V line
(T801, D841 to D844, C842, etc.).
Exchange the fuse F801.
Is a voltage of 10 V
supplied to pin 1 of the
connector E15?
Is a voltage of 5 V
supplied to pin 4
of IC3111?
Exchange U-Module
Unsolder pin 1
of the connector E15
and check if a voltage of
10 V is supplied to pin 1
of the connector
D15.
D841 to D844, C842
short-circuit inspection,
exchange
IC3111, C3124 short-circuit
inspection, exchange
IC3111 open inspection, C3071,
C3098 short-circuit inspection,
exchange
Yes
Yes
Yes
No
No
No
No
Yes
& !"#$
Page of 46
Display