(2)Flashing timing table
When an abnormality has occurred for a power supply line, the protection circuit (power supply protector/detection of abnormal
high voltage) operate and cuts the power supply. At this time, the defective line can be identified by the number of flashes (red) of
the "Power supply/function standby/video reception" indication at the front of the unit by means of the fault line which has oper-
ated the protection circuit.
high voltage) operate and cuts the power supply. At this time, the defective line can be identified by the number of flashes (red) of
the "Power supply/function standby/video reception" indication at the front of the unit by means of the fault line which has oper-
ated the protection circuit.
*Other than the above, the contents partly may differ according to the fault location.
•
Flashing twice: +6 V voltage drop (-> refer to the flowchart on page 9)
•
Flashing three times: +6 V voltage drop (-> refer to the flowchart on page 10)
•
Flashing four times: +130 V/+208 V voltage drop (refer to the flowchart on pages 11 and 12)
•
Flashing five times: +23 V voltage drop (-> refer to the flowchart on page 9)
•
Flashing six times: +15 V/+23 V voltage drop (refer to the flowchart on pages 13 and 14)
Flashing
Flashing timing
Contents
Once
Twice
Three times
Four times
Five times
Six times
Seven times
Once
3 sec
No Light
Light
CRT drive +32 kV
voltage rise ( g )
voltage rise ( g )
RGB drive +208 V,
vertical drive -15 V
voltage drop ( b )
vertical drive -15 V
voltage drop ( b )
Vertical drive +15 V/ -15 V,
+23 V/audio +23 V
voltage drop ( a )
+23 V/audio +23 V
voltage drop ( a )
+15 V/+ 12 V/+9 V/+5 V
/+3.3 V/BT +30 V
voltage rise ( d )
/+3.3 V/BT +30 V
voltage rise ( d )
+3.3 V voltage drop ( f )
+130 V overcurrent
detection ( c )
detection ( c )
+5 V voltage drop ( e )
% !"#$