KX-TGK310RUB, KX-TGK320RUB, KX-TGKA31RUB - Panasonic Telephone Service Manual (repair manual). Page 11

Read Panasonic KX-TGK310RUB / KX-TGK320RUB / KX-TGKA31RUB Service Manual online

11
KX-TGK310SP/KX-TGK310JT/KX-TGK320JT/KX-TGK310FR/KX-TGK310RU/KX-TGK320RU/KX-TGK310NE//KX-TGK310GR/KX-TGKA31EX/KX-TGKA31RU
4.3.4.
Power Supply Circuit/Reset Circuit
The power supply voltage from AC adaptor is converted to VBAT (3.0V) in IC302. And +3.0V for peripherals and analog part is
insulated from VBAT by Doubler of BBIC.
Circuit Operation:
5.5V
VBAT
RSTN(Reset) 
pin 54
VBAT
pin 10
pin 57
pin 9
pin 15
IC501
IC302
IC601
BBIC
DOUBLER OUT
For peripherals
VDDC (1.2V)
AC Adaptor
3.0V
REGULATOR
FLASH
IC611
EEPROM
+3.0V
STM/CKM
Receive
Amp.
RF Part
Startmonitor
(IC501 57pin)
VDDC (1.2 V)
VBAT
Reset (RSTN) 
(IC501_54 pin)
BBIC chip initialize
(CKM/STM)
Q171
* For KX-TGK320 only