KX-TGC310RU, KX-TGC312RU, KX-TGC320RU, KX-TGC322RU, KX-TGC310UC, KX-TGC312UC, KX-TGC320UC, KX-TGCA30RU - Panasonic Telephone Service Manual (repair manual). Page 11

Read Panasonic KX-TGC310RU / KX-TGC312RU / KX-TGC320RU / KX-TGC322RU / KX-TGC310UC / KX-TGC312UC / KX-TGC320UC / KX-TGCA30RU Service Manual online

11
KX-TGC310/KX-TGC312/KX-TGC320/KX-TGC322/KX-TGCA30
KX-TGC310/KX-TGC312/KX-TGC320/KX-TGC322/KX-TGCA30
KX-TGC310/KX-TGC312/KX-TGC320/KX-TGC322/KX-TGCA30
4.3.4.
Power Supply Circuit/Reset Circuit
The power supply voltage from AC adaptor is converted to VBAT (3.0V) in IC302. And +3.0V for peripherals and analog part is
insulated from VBAT by Doubler of BBIC.
Circuit Operation:
5.5V
VBAT
RSTN(Reset) 
pin 54
VBAT
pin 10
pin 57
pin 9
pin 15
IC501
IC302
IC601
BBIC
DOUBLER OUT
For peripherals
VDDC (1.2V)
AC Adaptor
3.0V
REGULATOR
FLASH
IC611
EEPROM
+3.0V
STM/CKM
Receive
Amp.
RF Part
ANS LED
MSG LED
Startmonitor
(IC501 57pin)
VDDC (1.2 V)
VBAT
Reset (RSTN) 
(IC501_54 pin)
BBIC chip initialize
(CKM/STM)
Q171
Page of 83
Display