KX-TG8081RUB, KX-TGA806RUB - Panasonic Telephone Service Manual (repair manual). Page 18

Read Panasonic KX-TG8081RUB / KX-TGA806RUB Service Manual online

18
KX-TG8081RUB/KX-TGA806RUB
Frequently Used Items (Base Unit)
ex.)
Note:
(*1) Refer to Registering a Handset to a Base Unit in the Operating Instructions.
(*2) When you enter the address or New Data, please refer to the table below.
(*3)
Items
Address
Default Data
New Data
Remarks
C-ID (FSK) sensitivity
05 70
00
01 (6 dBm up)
02 (12 dBm 
up)
When hex changes from “00” to “01” or “02”,
gain increases by 6 dBm or 12 dBm.
Frequency
00 08/00 07
02/70
-
-
Use these items in a READ-ONLY mode to
confirm the contents. Careless rewriting may
cause serious damage to the computer system.
ID
00 02~00 06
Given value
-
-
Bell length
02 46
32 (5 sec) (*3)
1E (3 sec)
14 (2 sec)
This is time until bell stops ringing.
(Unit: 100 msec)
PULSE Dial speed
(10PPs->20PPs)
02 21
28 (40 msec) 
(*3)
14 (20 msec)
-
This is pulse make time. (Unit: 1 msec)
02 22
3C (60 msec) 
(*3)
 1E (30 msec)
-
This is pulse break time. (Unit: 1 msec)
02 35
57 (870 msec) 
(*3)
2C (440 msec)
-
This is inter-digit time in pulse mode. (Unit: 10
msec)
Desired Number (hex)
Input Keys
Desired Number (hex)
Input Keys
0
0
A
[R]  +  0
1
1
B
[R]  +  1
.
.
C
[R]  +  2
.
.
D
[R]  +  3
.
.
E
[R]  +  4
9
9
F
[R]  +  5
Bell length
32(hex) = 50(dec) 
→ 50 × 100 msec = 5000 msec (5 sec)
PULSE Dial speed 
(10PPS -> 20PPS)
28 (hex) = 40 (dec) 
→ 40 × 1 msec = 40 msec
3C (hex) = 60 (dec) 
→ 60 × 1 msec = 60 msec 
57 (hex) = 87 (dec) 
→ 87 × 10 msec = 870 msec