9
(H)* BBIC Clock Adjustment
CLK
1. Apply 2.6 V between BATT+ and BATT- with DC power.
2. Input Command “sendchar sfr”, then you can confirm the current value.
3. Check X’tal Frequency. (10.368 MHz ± 20 Hz).
4. If the frequency is not 10.368 MHz ± 20 Hz, adjust the frequency of CLK
2. Input Command “sendchar sfr”, then you can confirm the current value.
3. Check X’tal Frequency. (10.368 MHz ± 20 Hz).
4. If the frequency is not 10.368 MHz ± 20 Hz, adjust the frequency of CLK
executing the command “sendchar sfr xx xx (where xx is the value)” so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
Note:
Clear the registered information for Base Unit before measurement, because the
Frequency will not possibly get stable due to the registered information.
Pressing the button of "3" "5" "7" "#"clears the registration.
Register to it on Base Unit after measurement.
Frequency will not possibly get stable due to the registered information.
Pressing the button of "3" "5" "7" "#"clears the registration.
Register to it on Base Unit after measurement.
IC1, X1, C47
(I)*
Transmitted Power
Confirmation
-
Remove the Antenna before starting step from 1 to 4.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: PP
• RFPI: 0102030405
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• RF LEVEL = -70 dBm
• PACKET: PP32Z
• RFPI: 0102030405
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• RF LEVEL = -70 dBm
• PACKET: PP32Z
2. Execute the command “sendchar TST 01 02 03 04 05".
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is 19 dBm ~ 25 dBm.
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is 19 dBm ~ 25 dBm.
IC1,
C802~C803,
C805, C806,
C805, C806,
C810, L809,
C811, C814,
R806, C825,
DA801
(J)* Modulation Check and
Adjustment
-
Follow steps 1 to 3 of (K).
4.Confirm that the B-Field Modulation is -350 ± 50/+350 ± 50 kHz/div &
Modulated width 610 kHz using data type Fig 31.
Modulated width 610 kHz using data type Fig 31.
IC1
(K)*
Frequency Offset
Confirmation
-
Follow steps 1 to 3 of (I).
4.Confirm that the frequency Offset is < ± 20 kHz.
IC1
(L)*
Frequency Drift
Confirmation
-
Follow steps 1 to 3 of (I).
4.Confirm that the frequency Drift is < ± 20 kHz/ms.
IC1
(M)*
Sensitivity Receiver
Confirmation
-
Follow steps 1 to 3 of (I).
4.Set DECT tester power to -88 dBm.
5.Confirm that the BER is < 1000 ppm.
5.Confirm that the BER is < 1000 ppm.
IC1,
C802~C804,
C826, C837,
C820, C822,
C826, C837,
C820, C822,
DA801, R807
(N)*
Power RAMP
Confirmation
-
Follow steps 1 to 3 of (I).
4.Confirm that Power RAMP is matching.
IC1
(O)
Audio Check and
Confirmation
-
1. Link to BASE which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 50 mA.
3. Input -45 dBm(600
2. Set line voltage to 48 V and line current to 50 mA.
3. Input -45 dBm(600
)/1 kHz to MIC of Handset. Measure the Level at Line I/F
and distortion level.
4. Confirm that the level is -2.0 dBm and that the distortion level is <5% at TEL
Line (600
Load).
5. Input -20 dBm(600
)/1 kHz to Line I/F. Measure the Level at Receiver of
Handset and distortion level (Receive volume set to second position from
minimum).
minimum).
6. Confirm that the level is -24 dBm and that the distortion level is <5% at
Receiver (34
Load).
IC1, C12, C96,
C97, R215,
R27, RA4,
C11, C13,
R28, MIC
(P) SP phone Audio Check
and Confirmation
-
1. Link to Base which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 50 mA.
3. Set the handset off-hook using SP-Phone key.
4. Input -30 dBm(600
2. Set line voltage to 48 V and line current to 50 mA.
3. Set the handset off-hook using SP-Phone key.
4. Input -30 dBm(600
)/1KHz to Line I/F and measure Receiving level at SP+
and SP-.
5. Confirm that the level is -6 dBm ± 3 dBm and that the distortion level is < 5%.
(vol = Max at SP (8
Load))
IC1, C12, C73,
D13, D14,
MIC, C11,
C13, RA4,
R27, R28,
C96, C97,
C96, C97,
R215, C72,
C73
(Q)
Charge Pump 3.0V
Supply Confirmation
CP3.0V
1. Confirm that the voltage between testpoint CP3.0V and GND is 3.0 V ± 0.3 V.
C704, C53,
C54
(R)
Charge Pump CPV2
4.0V Supply
Confirmation
CPV2
1. Confirm that the voltage between testpoint CPV2 and GND is 4.0 V ± 0.3 V.
(Power is supplied when LED in on)
C52, C55
(S)
Charge Pump CP2.8V
Supply Confirmation
CP2.8V
1. Confirm that the voltage between testpoint CPV2.8V and GND is 2.8 V ± 0.3 V.
C49, C53,
C54, D3, C51
Items
Check
Point
Procedure
Check or
Replace Parts
Click on the first or last page to see other KX-TG8061RUB / KX-TG8061UAB / KX-TG8061CAB / KX-TGA806RUB (serv.man3) service manuals if exist.