11.4. Adjustment Standard (Charger Unit)
When connecting the simulator equipment for checking, please refer to below.
11.4.1. Bottom View
Note:
(A) is referred to Check Point (Charger Unit) (P.38)
A
PNLB1922Z
3.0A
F1
PbF
-IG
Charge-
Charge+
12    /2 W
Digital
Volt Meter
DC POWER
DC 5.5 V
(GND)