KX-TG7127UAS, KX-TG7127UAT, KX-TGA711UAS, KX-TGA711UAT - Panasonic Telephone Service Manual (repair manual). Page 30

Read Panasonic KX-TG7127UAS / KX-TG7127UAT / KX-TGA711UAS / KX-TGA711UAT Service Manual online

30
KX-TG7127UAS/KX-TG7127UAT/KX-TGA711UAS/KX-TGA711UAT
03D1
1
EEP_RuRcvDigitBeforeRe
q
Receive Digit Before REQ
Default: 2digit 
0x02
x
03D2
1
EEP_PseudoBellLength
Pseudo Bell/RBT Length
Unit: 10ms, Default: 800ms 
0x50
x
03D3
1
EEP_PseudeBellToRbtLen Pseudo Bell to RBT/RBT to Pesude Bell Length
Unit: 100ms, Default: 1200ms 
0x0C
x
03D4
1
EEP_PseudoBellEndTimeo
ut
Pseudo Bell End Timeout
Unit: 1s, Default: 120s 
0x78
x
03D5
1
EEP_DtasMinDuration
DTAS minimum duration
Unit: 10ms, Default: 60ms 
0x06
x
03D6
1 EEP_DtasMaxDuration
DTAS maximum duration
Unit: 10ms, Default: 130ms 
0x0D
x
03D7
1 EEP_CasMinDuration
CAS minimum duration
Unit: 10ms, Default: 60ms 
0x06
x
03D8
1
EEP_CasMaxDuration
CAS maximum duration
Unit: 10ms, Default: 130ms 
0x0D
x
03D9
1
EEP_DtmfMinDuration
DTMF minimum duration
Unit: 10ms, Default: 20ms 
0x02
x
03DA
1
EEP_DtmfMaxDuration
DTMF maximum duration
Unit: 10ms, Default: disable(0xFF) 
0xFF
x
03DB
1
EEP_RuDtmfDurationMin RU_DTMF minimum duration
Unit: 10ms, Default: 10ms 
0x01
x
03DC
1
EEP_RuDtmfDurationMax RU_DTMF maximum duration
Unit: 10ms, Default: 70ms 
0x07
x
03DD
1
EEP_RuDtmfDurationOff RU_DTMF Off duration
Unit: 10ms, Default: 50ms 
0x05
x
0D62
3 EEP_RuClipReqLength
Length of REQ signal
Unit: 10ms, Default: 140ms 
0x0E
x
0D63
3
EEP_RuClipDelayBetween
Req
Delay between REQ signal
Unit: 10ms, Default: 200ms 
0x14
x
0D64
3 EEP_RuClipRepeatReq
Number of repeat REQ request Sent
Default: 3 repeat 
0x03
x
0D65
3
EEP_RuClipDelayBeforeR
eq
Delay before Send REQ signal
Unit: 10ms, Default: 200ms 
0x14
x
0D66
3
EEP_RuClipOnOff
Russian CLIP On/Off
0x01
x
0D67
3
EEP_RuClipRingNumBefor
eSequence
Number Of Rings Patterns Before Start Sequence
Default: 1 
0x01
x
0D92
3
EEP_RuClipDisplayDigit Number Of digits to be displayed
Default:7 digits 
0x07
x
Address Initial
Type
Name
 Description
Default value
Country
Setting
Page of 98
Display