KX-TG7107UAS, KX-TG7107UAT, KX-TG7108UAS, KX-TG7108UAT, KX-TGA710UAS, KX-TGA710UAT - Panasonic Telephone Service Manual (repair manual). Page 43

Read Panasonic KX-TG7107UAS / KX-TG7107UAT / KX-TG7108UAS / KX-TG7108UAT / KX-TGA710UAS / KX-TGA710UAT Service Manual online

43
KX-TG7107UAS/KX-TG7107UAT/KX-TG7108UAS/KX-TG7108UAT/KX-TGA710UAS/KX-TGA710UAT
(M)
Sensitivity Receiver 
Confirmation
-
Follow steps 1 to 6 of (I).
7.Set DECT tester power to -90 dBm.
8.Confirm that the BER is < 1000 ppm.
IC7, IC10, L7, 
L3, L4, L6, 
C117, C118, 
C119, C120, 
C124, C125, 
R106, R109, 
DA1, C102, 
R102, R103, 
Q10, C110, 
C112, R111, 
C126, C127, 
R112
(N)
Timing Confirmation
-
Follow steps 1 to 6 of (I).
7.Confirm that the Timing accuracy is < ± 2.0 ppm.
IC7, IC10, L7, 
L3, L4, L6, 
C117, C118, 
C119, C120, 
C124, C125, 
R106, R109, 
DA1, C102, 
R102, R103, 
Q10, C110, 
C112, R111, 
C126, C127, 
R112
(O)* RSSI Level Confirmation
-
Follow steps 1 to 6 of (I).
7.Execute the command “readrssi”.
8. Confirm that the returned value is 22 ± A (hex).
IC7, IC10, L7, 
L3, L4, L6, 
C117, C118, 
C119, C120, 
C124, C125, 
R106, R109, 
DA1, C102, 
R102, R103, 
Q10, C110, 
C112, R111, 
C126, C127, 
R112
(P) Power RAMP Confirma-
tion
-
Follow steps 1 to 6 of (I).
7.Confirm that Power RAMP is matching.
IC7, IC10, L7, 
L3, L4, L6, 
C117, C118, 
C119, C120, 
C124, C125, 
R106, R109, 
DA1, C102, 
R102, R103, 
Q10, C110, 
C112, R111, 
C126, C127, 
R112
(Q)*
Audio Check
-
1. Link with Handset.
2. Input -45dBm/1kHz to MIC of Handset.
Measure the Level at Line I/F and distortion level.
3. Confirm that the level is -10 dBm ± 2 dBm and that the distortion level is < 5%
at TEL Line (600 
Ω Load).
4. Input -20 dBm/1 kHz to Line I/F.
Measure the level at Receiver of Handset and distortion level
(*Receive volume set to second position from minimum). 
5. Confirm that the level is -21 dBm ± 2 dBm and that the distortion level is < 5%
at Receiver (volume: 1).
IC7, CN1, SA1, 
L1, L2, D3, Q3, 
Q4, R14, R15, 
R16, R17
(R)
Charging Check
-
1. Connect Charge Contact 12 
Ω/2 W resistor between charge+ and charge-.
2. Measure and confirm voltage across the resistor is 3.10 V ± 0.2 V.
R55, R56, C48, 
C49
Items
Check 
Point
Procedure
Check or 
Replace Parts
Page of 90
Display

Click on the first or last page to see other KX-TG7107UAS / KX-TG7107UAT / KX-TG7108UAS / KX-TG7108UAT / KX-TGA710UAS / KX-TGA710UAT service manuals if exist.