KX-TG6611RUB, KX-TG6611RUM, KX-TG6611UAB, KX-TG6611UAM, KX-TG6611CAB, KX-TG6611CAM, KX-TG6612CAB, KX-TGA661RUB, KX-TGA661RUM - Panasonic Telephone Service Manual (repair manual). Page 40

Read Panasonic KX-TG6611RUB / KX-TG6611RUM / KX-TG6611UAB / KX-TG6611UAM / KX-TG6611CAB / KX-TG6611CAM / KX-TG6612CAB / KX-TGA661RUB / KX-TGA661RUM Service Manual online

40
KX-TG6611RU/KX-TG6611UA/KX-TG6611CA/KX-TG6612CA/KX-TGA661RU
(L)*
Frequency Drift 
Confirmation
-
Follow steps 1 to 3 of (I).
4.Confirm that the frequency Drift is < ± 20 kHz/ms.
IC1, 
C802~C806, 
C809~C814, 
C820, C822, 
C823, 
C825~C826, 
L802, C863, 
C864, L803, 
DA801, R806, 
R807
(M)*
Sensitivity Receiver 
Confirmation
-
Follow steps 1 to 3 of (I).
4.Set DECT tester power to -88 dBm.
5.Confirm that the BER is < 1000 ppm.
IC1, 
C802~C806, 
C809~C814, 
C820, C822, 
C823, 
C825~C826, 
L802, C863, 
C864, L803, 
DA801, R806, 
R807
(N)*
Power RAMP 
Confirmation
-
Follow steps 1 to 3 of (I).
4.Confirm that Power RAMP is matching.
IC1, 
C802~C806, 
C809~C814, 
C820, C822, 
C823, 
C825~C826, 
L802, C863, 
C864, L803, 
DA801, R806, 
R807
(O)
Audio Check and 
Confirmation
-
1. Link to BASE which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 50 mA.
3. Input -45 dBm (600 
Ω)/1 kHz to MIC of Handset. Measure the Level at Line I/F
and distortion level.
4. Confirm that the level is -2.0 dBm and that the distortion level is <5%    at TEL
Line (600 
Ω Load).
5. Input -20 dBm (600 
Ω)/1kHz to Line I/F. Measure the Level at Receiver of
Handset and distortion level (Receive volume set to second position from
minimum).
6. Confirm that the level is -24 dBm and that the distortion level is <5% at
Receiver (34 
Ω Load).
IC1, C12, C96, 
C97, R215, 
R27, RA4, 
C11, C13, 
R28, MIC
(P) SP phone Audio Check 
and Confirmation
-
1. Link to Base which is connected to Line Simulator.
2. Set line voltage to 48V and line current to 50 mA.
3. Set the handset off-hook using SP-Phone key.
4. Input -30 dBm(600 
Ω)/1 KHz to Line I/F and measure Receiving level at SP+
and SP-.
5. Confirm that the level is -8.0 dBm and that the distortion level is < 5%. 
(Val = Max at SP (8 
Ω Load))
IC1, C12, C73, 
D13, D14, 
MIC, C11, 
C13, RA4, 
R27, R28, 
C96, C97, 
R215, C72, 
C73
(Q)
Charge Pump 3.0V 
Supply Confirmation
CP3.0V
1. Confirm that the voltage between testpoint CP3.0V and GND is 3.0 V - 0.1/+0.3
V.
C49, C53, C54
(R)
Charge Pump CPV2 
3.0V Supply 
Confirmation
CPV2
1. Confirm that the voltage between testpoint CPV2 and GND is 3.0 V ± 0.3 V.
(Power is supplied when LED in on)
C52, C55 
(S)
CP2.8V
Confirmation
CP2.8V
1. Confirm that the voltage between testpoint CPV2.8V and GND is 4.0 V ± 0.3 V.
D3, C51 
Items
Check 
Point
Procedure
Check or 
Replace Parts
Page of 82