KX-TG6541RUB, KX-TGA651RUB, KX-TGA405RUB - Panasonic Telephone Service Manual (repair manual). Page 36

Read Panasonic KX-TG6541RUB / KX-TGA651RUB / KX-TGA405RUB Service Manual online

36
KX-TG6541RUB/KX-TGA651RUB/KX-TGA405RUB
9.1.4.3.
Check Table for RF part
Note:
(*1) Refer to Adjustment Standard (Base Unit) (P.56)
(*2) Refer to Adjustment Standard (Handset) (P.61)
9.1.4.4.
Check Table for Range Extender RF part
Note:
(*3) Adjustment Standard (Range Extender) (P.62)
No.
Item
BU (Base Unit) Check
HS (Handset) Check
1
Link Confirmation Normal
HS, BU Mode: [Normal mode]
1. Register Regular HS to BU (to be 
checked).
2. Press [Talk] key of the Regular HS to 
establish link.
1. Register HS (to be checked) to Regular 
BU.
2. Press [Talk] key of the HS to establish link.
2
X’tal Frequency confirmation
1. Check X’tal Frequency. (*1)
(10.368 MHz ± 100 Hz)
1. Check X’tal Frequency. (*2)
(10.368 MHz ±100Hz)
3
Range Confirmation Normal
HS, BU Mode: [Normal mode]
1. Register Regular HS to BU (to be 
checked).
2. Press [Talk] key of the Regular HS to 
establish link.
3. Compare the range of the BU (being 
checked) with that of the Regular BU.
1. Register HS (to be checked) to Regular 
BU.
2. Press [Talk] key of the HS to establish link.
3. Compare the range of the HS (being 
checked) with that of the Regular HS.
No.
Item
RE(Range Extender) Check
1
Link Confirmation
HS Mode [Test Mode]
1. Register Regular HS and RE (to be checked) to Regular BU.
2. HS is power ON with “1“, “6“and “#“.
3. Press [Talk] key of the Regular HS to establish link through RE.
2
X
'
tal Frequency confirmation
RE Mode: [Adjustment]
Check X
'
tal Frequency.
(13.824000 MHz ±100 Hz)
3
TX confirmation
Regular HS Mode:
[Test RX Mode]
RE Mode:
[Test TX_Burst Mode]
1. Place Regular HS 15 cm away from a checked RE.
2. Confirm "TXDATA" waveform of RE (*3) and “RXDATA“  waveform of Regular HS by Digital 
Oscilloscope. 
4
RX confirmation
Regular HS Mode:
[Test TX_Burst Mode] 
RE Mode:
[Test RX Mode]
1. Place Regular HS 15 cm away from a checked RE.
2. Confirm "RXDATA" waveform of RE (*3) and “TXDATA“  waveform of Regular HS by Digital 
Oscilloscope. 
5
Range Confirmation Normal
BU, RE Mode: [Normal Mode]
HS Mode: Test mode
1. Place Regular HS and RE (to be checked) to Regular BU.
2. HS is power ON with “1“, “6“and “#“.
3. Press [Talk] key of the Regular HS to establish link. 
4. Compare the range of the RE (being checked) with that of the Regular RE
Page of 104