KX-TG6521RUB, KX-TG6521RUT, KX-TG6522RUT, KX-TGA651RUB, KX-TGA651RUT, KX-TG6522RU1 - Panasonic Telephone Service Manual (repair manual). Page 41

Read Panasonic KX-TG6521RUB / KX-TG6521RUT / KX-TG6522RUT / KX-TGA651RUB / KX-TGA651RUT / KX-TG6522RU1 Service Manual online

41
KX-TG6521RUB/KX-TG6521RUT/KX-TG6522RUT/KX-TGA651RUB/KX-TGA651RUT
(F)* Battery Monitor Check
-
1. Apply 2.25 V between BATT+ and BATT-.
2. Execute the command 
sendchar PAD
sendchar LED 0
sendchar CRX 0 1
sendchar AD1
It assumes that the return value is XX.
a) 6c   XX   71: No need to adjust
b) XX: 6A ~ 6B: Need to adjust
XX: 72 ~ 74: Need to adjust
Write AD value of 2.25 V to EEPROM.
ex) read data: XX = 6A, write data: YY = 6A
read data: XX = 73, write data: YY = 73
EEPROM = 0004(Low Voltage) write “YY”
Execute the command “wreeprom 00 04 01 YY”.
EEPROM = 0005(No Voltage) write ‘’YY - 1D’’
Execute the command “×wreeprom 00 05 01 ZZ”.
EEPROM = 000A(Low Voltage BL) write “YY - 16”
Execute the command “wreeprom 00 0A 01 WW”.
Note:
ZZ = YY - C
No Voltage writing data limit is ‘00’.
c) XX: 00 ~ 69: Reject
XX: 75 ~ FF: Reject
IC1, F1, C1, 
R45
(G)
Battery Low Confirma-
tion
-
1. Apply 2.40 V between BATT+ and BATT-.
2. Confirm that there is no flashing of Battery Icon.
3. Apply 2.25 V ± 0.08 V between BATT+ and BATT-.
4. Confirm that there is flashing of Battery Icon.
IC1, F1, C1, 
R45
(H)* BBIC Clock Adjustment
CLK
1. Apply 2.6 V between BATT+ and BATT- with DC power.
2. Input Command “sendchar sfr”, then you can confirm the current value.
3. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
4. If the frequency is not 10.368 MHz ± 100 Hz, adjust the frequency of CLK exe-
cuting the command “sendchar sfr xx xx (where xx is the value)” so that the
reading of the frequency counter is 10.368000 MHz ± 5 Hz.
Note:
Clear the registered information for Base Unit before measurement, because the
Frequency will not possibly get stable due to the registered information.
Pressing the button of “3” “7” “9” “#” clears the registration.
Register to it on Base Unit after measurement. 
IC1, X1, C47
 
(I)* Transmitted Power Con-
firmation
-
Remove the Antenna before starting step from 1 to 4.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: PP
• RFPI: 0102030405
• Traffic Carrier: 5
• Traffic Slot: 4
• Mode: Loopback
• RF LEVEL = -70 dBm
• PACKET: PP32Z
2. Execute the command “sendchar TST 01 02 03 04 05".
3. Initiate connection from DECT tester.
4. Confirm that the NTP value at ANT is 19 dBm ~ 25 dBm.
IC1, 
C802~C806, 
C808~C814, 
C819~C820, 
C822, 
C825~C827, 
C834, 
C860~C864, 
L801~L804, 
DA801, 
R801~R808
(J)* Modulation Check and 
Adjustment
-
Follow steps 1 to 3 of (K).
4.Confirm that the B-Field Modulation is -370±30/ +370±30 kHz/div & Modulated
width   690 kHz using data type Fig 31.
IC1, 
C802~C806, 
C808~C814, 
C819~C820, 
C822, 
C825~C827, 
C834, 
C860~C864, 
L801~L804, 
DA801, 
R801~R808
Items
Check 
Point
Procedure
Check or 
Replace Parts
Page of 88
Display