40
KX-TG6461RUT/KX-TGA641RUT
(R)
Audio Check
-
(Through Cordless handset)
1. Link with cordless handset.
2. Input -45 dBm (600
2. Input -45 dBm (600
Ω)/1KHz to MIC of cordless handset.
Measure the Level at Line I/F and distortion level.
3. Confirm that the level is -5 dBm ± 2 dBm and that the distortion level is < 5 %
at TEL Line (600
Ω Load).
4. Input -20 dBm (600
Ω)/1KHz to Line I/F.
Measure the level at Receiver of cordless handset and distortion level
(*Set Receive volume to first position from minimum).
(*Set Receive volume to first position from minimum).
5. Confirm that the level is -20 dBm ± 2 dBm and that the distortion level is < 5 %
at Receiver (150
Ω Load).
P101,D101,
Q111,Q112,
Q111,Q112,
R110,R112,
R123,R115,
R117,R118,
D117Q131,
C151,R153,
R154,C152,
C154,C155,
R131,C142,
R146,IC501
R154,C152,
C154,C155,
R131,C142,
R146,IC501
-
(Through SP-PHONE)
1. Press Answer key ON.
2. Input -45 dBm (600
2. Input -45 dBm (600
Ω)/1KHz to the terminal for SP_Phone MIC on the Base
unit.
3. Measure and check the level at line I/F is -1.5 dBm ± 2dBm and that the dis-
tortion level is < 5% at TEL Line (600
Ω).
4. Input -20 dBm (600
Ω)/1KHz to Line I/F.
5. Measure and check the level at the terminal for SP_Phone receiver of the
Base unit is -12 dBm ± 2dBm and that distortion level is <5% (Set Receivr vol-
ume set to 5th position from minimum, On the measurement connection.)
ume set to 5th position from minimum, On the measurement connection.)
Refer to Adjustment Standard (Base Unit) (P.54).
In addition to
(through Cord-
less handset)
IC201,L203,
L204,L201,
L201,SP,
Mic,R233,
R234,C232-234
D235,R232,
C235,R236
-
(Through Corded-Handset)
1. Set the Hook Switch to OFF-HOOK.
2. Input -45 dBm (600
2. Input -45 dBm (600
Ω)/1KHz to the terminal for Corded-handset MIC on the
Base unit.
3. Measure and check the level at line I/F is -13 dBm ± 2dBm and that the distor-
tion level is < 5% at TEL Line(600
Ω)
4. Input -20 dBm (600
Ω)/1KHz to Line I/F.
5. Measure and check the level at terminal for Corded-Handset receiver on Base
unit is -23 dBm ± 2dBm and that distortion level is <5% (Set Receiver volume
to second position from minimum, and load is 150
to second position from minimum, and load is 150
Ω instead of Receiver.)
Refer to Adjustment Standard (Base Unit) (P.54).
In addition to
(through cord-
less handset)
IC201,L221-
L224
R213,R214
C213,C214
C224,C227
R222,R224
C213,C214
C224,C227
R222,R224
Corded-handset
(S)*
TAM Operation
Confirmation
-
1. TAM Confirmation (Execute the command “sendchar_VPI”)
2. Confirm the returned Value (Value is “DAS7RN 02”).
2. Confirm the returned Value (Value is “DAS7RN 02”).
IC201,IC541
Q541
(T)* Power RAMP Confirma-
tion
-
Follow steps 1 to 6 of (K).
7.Confirm that Power RAMP is matching.
Items
Check
Point
Procedure
Check or
Replace Parts
Click on the first or last page to see other KX-TG6461RUT / KX-TGA641RUT service manuals if exist.