Read Panasonic KX-TG6451RUT / KX-TGA641RUT Service Manual online
38
KX-TG6451RUT/KX-TGA641RUT
(I)* Hookswitch Check with
DC Characteristics
-
1. Connect TIP/RING (Telephone Socket) to Tel-simulator which is connected
with 600
Ω.
2. Set line voltage to 48 V and line current to 40 mA at off-hook condition of nor-
mal telephone.
3. Execute the command “hookoff”
4. Confirm that the line current is 40 mA ± 5 mA.
5. Execute the command “hookon”.
6. Confirm that the line current is less than + 0.8 mA.
4. Confirm that the line current is 40 mA ± 5 mA.
5. Execute the command “hookon”.
6. Confirm that the line current is less than + 0.8 mA.
P101,D101,
Q111,Q112,
Q111,Q112,
R110,R111,
R112,R123,
R115,R117,
R118,D117
(J) DTMF Generator Check
-
1. Connect TIP/RING (Telephone Socket) to DTMF tester. (Load=600
Ω)
2. Link cordless handset and push dial key.
3. Confirm DTMF character.
4. Confirm that the high Group is -3 dBm ± 2 dBm.
5. Confirm that the low Group is -6 dBm ± 2 dBm.
3. Confirm DTMF character.
4. Confirm that the high Group is -3 dBm ± 2 dBm.
5. Confirm that the low Group is -6 dBm ± 2 dBm.
IC501,R154,
R153,C151,
Q131
(K)* Transmitted Power Con-
firmation
ANT2
Remove the Antenna before starting step from 1 to 7.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: FP
• Traffic Carrier: 2
• Traffic Slot: 4
• Mode: Loopback
• PMID: 00000
• RF LEVEL = -70 dBm.
• Traffic Carrier: 2
• Traffic Slot: 4
• Mode: Loopback
• PMID: 00000
• RF LEVEL = -70 dBm.
2. Execute the command “testmode”.
3. Execute the command “sendchar dmv 2 2”.
4. Check that “Signalling Status” has been set to “Locked”, then press “ACCEPT
3. Execute the command “sendchar dmv 2 2”.
4. Check that “Signalling Status” has been set to “Locked”, then press “ACCEPT
RFPI”.
5. Initiate connection from Dect tester (“set up connect”)
6. Execute the command “ANT2”.
7. Confirm that the NTP value at ANT is 19.0 dBm ~ 25.0 dBm.
6. Execute the command “ANT2”.
7. Confirm that the NTP value at ANT is 19.0 dBm ~ 25.0 dBm.
DA802,C859,
C803,DA801,
C803,DA801,
C812,L802,
IC801,IC501
(L)*
Modulation Check
ANT2
Follow steps 1 to 6 of (K).
7.Confirm that the B-Field Modulation is -370 ± 30/+370 ± 30 kHz/div using data
type Fig31.
type Fig31.
DA802,C859,
C803,DA801,
C803,DA801,
C812,L802,
IC801,IC501
(M)* Frequency Offset Check
ANT2
Follow steps 1 to 6 of (K).
7.Confirm that the frequency offset is < ± 50 kHz.
DA802,C859,
C803,DA801,
C803,DA801,
C812,L802,
IC801,IC501
(N)* Frequency Dirft Confir-
mation
ANT2
Follow steps 1 to 6 of (K).
7.Confirm that the frequency drift is < ± 35 kHz/ms.
C803,DA801,
C812,L802,
IC801,IC501
(O)*
Sensitivity Receiver
Confirmation
ANT2
Follow steps 1 to 6 of (K).
7.Set DECT tester power to -88 dBm.
8.Confirm that the BER is < 1000 ppm.
8.Confirm that the BER is < 1000 ppm.
DA802,C859,
C803,DA801,
C803,DA801,
C826,R807,
C822,IC501
C822,IC501
(P)*
Timing Confirmation
ANT2
(Through Cordless handset)
Follow steps 1 to 6 of (K).
Follow steps 1 to 6 of (K).
7.Confirm that the Timing accuracy is
• ± 5.0 ppm (When adjust the frequency of CLK in them (H).
• ± 15.0 ppm (When do not adjust the frequency of CLK in them (A).
• ± 15.0 ppm (When do not adjust the frequency of CLK in them (A).
DA802,C859,
C803,DA801,
C803,DA801,
C812,L802,
IC801,IC501
(Q)* RSSI Level Confirmation
ANT2
Follow steps 1 to 6 of (K).
7.Execute the command “readrssi”.
8. Confirm that the returned value is 22 ± A (hex).
8. Confirm that the returned value is 22 ± A (hex).
DA802,C859,
C803,DA801,
C803,DA801,
C826,R807,
C822,IC501
C822,IC501
Items
Check
Point
Procedure
Check or
Replace Parts
Click on the first or last page to see other KX-TG6451RUT / KX-TGA641RUT service manuals if exist.