KX-TG5511UAB, KX-TG5511UAR, KX-TGA550RUB, KX-TGA550RUR, KX-TGA551RUB, KX-TGA551RUR - Panasonic Telephone Service Manual (repair manual). Page 55

Read Panasonic KX-TG5511UAB / KX-TG5511UAR / KX-TGA550RUB / KX-TGA550RUR / KX-TGA551RUB / KX-TGA551RUR Service Manual online

55
KX-TG5511UA/KX-TGA550RU/KX-TGA551RU
11.7.1.2. Handset
First, operate the PC setting according to The Setting Method of JIG (Handset)(P.51).
Then download the appropriate data according to the following procedures.
Note:
(*3) ZZ: country code, XXX_YYY: revision number
"ZZ", "XXX" and "YYY" vary depending on the country version. You can find them in the batch file, PNZZ- mentioned in The
Setting Method of JIG (Handset)
 (P.51).
(*4) Refer to Check Point (Handset) (P.39)
Items
How to download/Required adjustment
BBIC (FLASH type)
(IC1)
Programming data is stored in memory.
1) Make sure to connect the JIG cable, then disconnect the DC
Power in order to download the data.
2) Execute the command “flw480 *********.hex”.
3) Connect the DC Power.
4) Press and hold the handset Power key.
5) While holding down the handset Power key, press the PC
Enter key once.
6) After a few minutes, “Successful upgrade” is displayed  on
the PC indicating downloading has finished.
7) Detach the JIG cable, then press the handset Power key to
turn it on.
8) Connect the JIG cable again, and execute the command
"getchk”, then confirm the checksum value is correct.
• If the downloading fails, start again from step 1).
10) Default batch file: Execute the command “default.bat”.
11) Default batch file (remaining): Execute the command
“TGA550RUDEFrevXXX_YYY.bat”. (*3).
12) Country version batch file: Execute the command
“TGA550RUZZrevXXX_YYY.bat”. (*3).
13) Clock adjustment: Refer to Check Point (H). (*4).
14) 1.8 V setting and battery low detection: Refer to Check
Point (A), (F) and (G). (*4).
EEPROM (IC3)
Adjusted parameter data is stored in memory.
(country version batch file, default batch file,
etc.)
1) Default batch file: Execute the command “default.bat”.
2) Default batch file (remaining): Execute the command 
“TGA550RUDEFrevXXX_YYY.bat”. (*3)
3) Country version batch file: Execute the command 
“TGA550RUZZrevXXX_YYY.bat”. (*3)
4) Clock adjustment: Refer to Check Point (H). (*4)
5) 1.8 V setting and battery low detection: Refer to Check Point 
(A), (F) and (G). (*4)
X'tal (X1)
System clock
Clock adjustment data is in EEPROM, adjust the data again
after replacing it.
1) Refer to Check Point (C). (*4)
Page of 86