KX-TG5511UAB, KX-TG5511UAR, KX-TGA550RUB, KX-TGA550RUR, KX-TGA551RUB, KX-TGA551RUR - Panasonic Telephone Service Manual (repair manual). Page 47

Read Panasonic KX-TG5511UAB / KX-TG5511UAR / KX-TGA550RUB / KX-TGA550RUR / KX-TGA551RUB / KX-TGA551RUR Service Manual online

47
KX-TG5511UA/KX-TGA550RU/KX-TGA551RU
11 Measurements and Adjustments
This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in 
 Troubleshooting Guide (P.23)
11.1. Equipment Required
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm)
Hewlett Packard, 53131A is recommended.
• DECT tester: Rohde & Schwarz, CMD 60 is recommended.
This equipment may be useful in order to precisely adjust like a mass production.
11.2. The Setting Method of JIG (Base Unit)
This section explains the PC setting to use command required in Check Point (Base Unit)(P.35).
<Preparation>
• Serial JIG cable: PQZZ1CD300E*
• PC which runs in DOS mode
• Batch file CD-ROM for setting: PNZZTG5511UA
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
11.2.1. Connections
 Connect the AC adaptor to DC-JACK (base unit).
 Connect the JIG Cable GND (black) to GND.
 Connect the JIG Cable RX (red) to URX and TX (yellow) to UTX.
Note:
*: COM port names may vary depending on what your PC calls it.
Resistor
Old value (k
Ω) New value (kΩ)
R2
22
3.3
R3
22
3.3
R4
22
4.7
R7
4.7
10
1
2
3
Base unit P. C. board
UTX (yellow)
AC adaptor
1
3
2
3
GND (black)
URX (red)
To Serial Port
(COM port 1*)
JIG Cable
PC
GND
UTX
URX
Page of 86
Display

Click on the first or last page to see other KX-TG5511UAB / KX-TG5511UAR / KX-TGA550RUB / KX-TGA550RUR / KX-TGA551RUB / KX-TGA551RUR service manuals if exist.