KX-TG5511UAB, KX-TG5511UAR, KX-TGA550RUB, KX-TGA550RUR, KX-TGA551RUB, KX-TGA551RUR - Panasonic Telephone Service Manual (repair manual). Page 41

Read Panasonic KX-TG5511UAB / KX-TG5511UAR / KX-TGA550RUB / KX-TGA550RUR / KX-TGA551RUB / KX-TGA551RUR Service Manual online

41
KX-TG5511UA/KX-TGA550RU/KX-TGA551RU
(K)* Frequency Offset Confir-
mation
-
Follow steps 1 to 3 of (I).
4.Confirm that the frequency Offset is < ± 50 kHz.
IC1, 
C802~C806, 
C808~C814, 
C819~C820, 
C822, 
C825~C827, 
C834, 
C860~C864, 
L801~L804, 
DA801, 
R801~R808
(L)* Frequency Drift Confir-
mation
-
Follow steps 1 to 3 of (I).
4.Confirm that the frequency Drift is < ± 35 kHz/ms.
IC1, 
C802~C806, 
C808~C814, 
C819~C820, 
C822, 
C825~C827, 
C834, 
C860~C864, 
L801~L804, 
DA801, 
R801~R808
(M)*
Sensitivity Receiver 
Confirmation
-
Follow steps 1 to 3 of (I).
4.Set DECT tester power to -88 dBm.
5.Confirm that the BER is < 1000 ppm.
IC1, 
C802~C806, 
C808~C814, 
C819~C820, 
C822, 
C825~C827, 
C834, 
C860~C864, 
L801~L804, 
DA801, 
R801~R808
(N)* Power RAMP Confirma-
tion
-
Follow steps 1 to 3 of (I).
4.Confirm that Power RAMP is matching.
IC1, 
C802~C806, 
C808~C814, 
C819~C820, 
C822, 
C825~C827, 
C834, 
C860~C864, 
L801~L804, 
DA801, 
R801~R808
(O) Audio Check and Confir-
mation
-
1. Link to BASE which is connected to Line Simulator.
2. Set line voltage to 48V and line current to 50mA.
3. Input -45dBm(600
Ω)/1kHz to MIC of Handset. Measure the Level at Line I/F
and distortion level.
4. Confirm that the level is -2.5dBm±2 dBm and that the distortion level is <5% at
TEL Line (600
Ω Load).
5. Input -20dBm(600
Ω)/1kHz to Line I/F. Measure the Level at Receiver of
Handset and distortion level (Receive volume set to second position from
minimum).
6. Confirm that the level is -30.5dBm±2 dBm and that the distortion level is <5%
at Receiver (150
Ω Load).
IC1, C12, C96, 
C97, R215, 
R27, RA4, 
C11, C13, 
R28, D3, D4, 
MIC, R73, R74
(P) SP phone Audio Check 
and Confirmation
-
1. Link to Base which is connected to Line Simulator.
2. Set line voltage to 48V and line current to 50mA.
3. Set the handset off-hook using SP-Phone key.
4. Input -25 dBm(600
Ω)/1KHz to Line I/F and measure Receiving level at SP+
and SP-.
5. Confirm that the level is -11.0 dBm ± 2 dBm and that the distortion level is <
5%. (vol = 3)
IC1, C12, C73, 
D13, D14, 
R73, R74, 
MIC, C11, 
C13, RA4, 
R27, R28, 
C96, C97, 
R215, C72
(Q) Charge Pump 3.0V Sup-
ply Confirmation
CP3.0V
1. Confirm that the voltage between testpoint CP3.0V and GND is 3.0±0.3V.
C49, C52~C54
(R) Charge Pump 4.0V Sup-
ply Confirmation
CP4.0V
1. Confirm that the voltage between testpoint CP4.0V and GND is 4.0V ±0.3V.
C50, C51, C55
Items
Check 
Point
Procedure
Check or 
Replace Parts
Page of 86
Display

Click on the first or last page to see other KX-TG5511UAB / KX-TG5511UAR / KX-TGA550RUB / KX-TGA550RUR / KX-TGA551RUB / KX-TGA551RUR service manuals if exist.