KX-TG2560B, KX-TG2560S - Panasonic Telephone Service Manual (repair manual). Page 21

Read Panasonic KX-TG2560B / KX-TG2560S Service Manual online

21
KX-TG2560B/KX-TG2560S
Transmit Power Check: (     indicates the button of Marconi.)
Press "FLASH" button (TX Power on)
"REDIAL" button (SS on)
TP Tx ANA pull up wire open.
Set Marconi: Tx Test   : Select "Tx Test" Mode
TX Power
Broad/Narrow   : Select "Broad" Band Mode
Check TX Power reading more than +20 dBm - (Jig Loss from CN4 to CN3). When this value is NG, replace RF unit.
Receiving Sensitivity Check: (     indicates the button of Marconi.)
1. Connect audio cable positive lead to TP-AF ( 13 pin of CN600), negative lead to TP-GND ( 23 pin of CN600) and BNC
    end to AF INPUT on Marconi.
2. Set Marconi:
(a)  Rx Test : Select Rx Test
(b)  RF Gen   ON/OFF  : RF Output on
(c)  FREQ.
: Input Rx Freq.= 904.560MHz (CH1)
(d)  LEVEL : Input RF Level = (-30dBm)+(Fig Loss from CN1 to CN2)
(e)  Mod Gen   ON/OFF  : FM on
(f)   Freq.
: Input Audio Freq = 1.0kHz
(g)  LEVEL : Input FM dev Level = 24kHz
(h)  AF Filter   0.3 to 3.4k  : Select AF Filter
3. Press SINAD button until the display shows the SINAD value and press dB button.
4. Press "Amplitude" of Marconi. Lower the value of Amplitude so that SINAD is 12 dB.
5. When pin 13 of CN600 (AF Out) is touched, confirm that Amplitude value of Marconi is less than {(-105 dBm)+Jig Loss from
    CN1 to CN2)}. When this value is NG, replace RF unit.
Squelch Check:
1. Keep same RX TEST settings as in Receiving Sensitivity Check.
2. Connect scope (X1) positive lead to TP-SQL 15 pin of CN600 on RF UNIT, negative lead to TP-GND 23 pin of CN600 and
    BNC end to scope. Set scope to following condition.
     (a) TIME/DIV = 1 msec.
     (b) VOLT/DIV = 1 V
3. Set RF GEN LEVEL to [-95dBm +(Jig Loss CN1 
 CN2) (+8 dBµ Vemf)]. Check scope voltage is LOW.
4. Set RF GEN LEVEL to [-120dBm +(Jig Loss CN1 
 CN2) (-7 dBµ Vemf)]. Check the scope voltage is HIGH.
5. When the scope does not show above condition, press " RF Gen  and  LEVEL " of Marconi and lower the value of
   Amplitude so that SINAD is 12 dB.
   When TP - SQL is touched, adjust VR801 until scope voltage toggles between LOW & HIGH. When VR801 cannot be adjusted
   at this value, replace RF unit.
RSSI (Receiving Signal Strength Indicator) DC Voltage Check:
1. Set Marconi as same conditions of Receiving Sensitivity Check.
2. Connect positive lead of DC voltmeter to TP-RSSI and negative lead to TP-GND.
3. Confirm that RSSI value is +2.3 V±0.03 V.
4. When RSSI value is not +2.3 V±0.03 V, adjust the value at VR800. When RSSI cannot be adjusted at this value, replace
   RF unit.
RF UNIT
900MHz
Tx ANA
pull up
RX ANT
GND
CN2
CN1
CN3
ANT
Marconi
Mode: Rx Test
PN
CN4
1750MHz
Jig: PQZZTG200RF1
down converter
2.4GHz
GND
TX
RSSI
IC990
C991
CN102
TXANA
ANT
Marconi
Mode:
Tx Test
~
Page of 69
Display

Click on the first or last page to see other KX-TG2560B / KX-TG2560S service manuals if exist.