Read Panasonic KX-TG1611RUF / KX-TG1611RUH / KX-TG1611RUJ / KX-TG1611RUR / KX-TG1611RUW / KX-TG1612RU1 / KX-TG1612RU3 / KX-TG1612RUH / KX-TGA161RUF / KX-TGA161RUH / KX-TGA161RUJ / KX-TGA161RUR / KX-TGA161RUW Service Manual online
15
KX-TG1611RU/KX-TG1612RU/KX-TGA161RU
Frequency Used Items (Base Unit)
Note:
*: When you enter the address, please refer to the table below.
ex.)
(*1)
(*2)
Desired Number (hex)
Input Keys
Desired Number (hex)
Input Keys
0
0
A
Press and keep 1
1
1
B
Press and keep 2
.
.
C
Press and keep 3
.
.
D
Press and keep 4
.
.
E
Press and keep 5
9
9
F
Press and keep 6
Items (*2)
Address
Default Data
New Data
Remarks
C-ID (FSK) sensitivity
01 C1~ 01
C2
00 28
(3dB up)
00 A4
(6dB up)
00 E7
When hex changes from “0028” to “00A4” or
“00E7”, gain increases by 3dB or 6dB.
“00E7”, gain increases by 3dB or 6dB.
C-ID (DTMF) sensitivity
01 B7
34
(3dB up)
38
(6dB up)
3C
When hex changes from “34” to “38” or “3C”, gain
increases by 3dB or 6dB.
increases by 3dB or 6dB.
Frequency
01 63~ 01 64
Given value
-
-
Use these items in a READ-ONLY mode to confirm
the contents. Careless rewriting may cause serious
damage to the computer system.
the contents. Careless rewriting may cause serious
damage to the computer system.
ID
00 10~ 00 14
Given value
-
-
Bell length
015D~015E 02 EE(6sec) (*1)
01 77(3sec)
00 FA (2sec)
This is time until bell stops ringing. (Unit:8ms)
PULSE Dial speed
(10PPS -> 20PPS)
(10PPS -> 20PPS)
0129~012A
01 90(40msec)
(*3)
00 C8(20msec)
-
This is pulse make time. (Unit:0.1ms)
012B~012C
02 58(60msec)
(*3)
01 2C(30msec)
-
This is pulse break time. (Unit:0.1ms)
012D~012E 23 28(900msec)
(*3)
11 30(440msec)
-
This is inter-digit time in pulse mode.
(Unit:0.1ms)
(Unit:0.1ms)
Bell length
02EE(hex) = 750(dec)
→ 750 x 8msec = 6000msec(6sec)
PULSE Dial speed
(10PPS -> 20PPS)
(10PPS -> 20PPS)
0190(hex) = 400(dec)
→ 400 x 0.1msec = 40msec
0258(hex) = 600(dec)
→ 600 x 0.1msec = 60msec
2328(hex) = 9000(dec)
→ 9000 x 0.1msec = 900msec
Items
Description
C-ID (FSK) sensitivity
FSKGain_shiftgain
C-ID (DTMF) sensitivity
Foutgains:HPFilter Foutgains
Frequency
Setting value of FREQ_TRIM_REG
ID
ID
Bell length
Time until it stops bell.