Model
KX-TG1107UAS KX-TG1107UAT KX-TG1108UAS KX-TG1108UAT KX-TGA110UAS KX-TGA110UAT
Pages
87
Size
2.82 MB
Type
PDF
Document
Service Manual
Brand
Device
Telephone / DIGITAL CORDLESS PHONE
File
kx-tg1107uas-kx-tg1107uat-kx-tg1108uas-kx-tg1108ua.pdf
Date

Read Panasonic KX-TG1107UAS / KX-TG1107UAT / KX-TG1108UAS / KX-TG1108UAT / KX-TGA110UAS / KX-TGA110UAT Service Manual online

KX-TG1107UAS
KX-TG1107UAT
KX-TG1108UAS
KX-TG1108UAT
KX-TGA110UAS
KX-TGA110UAT
Digital Cordless Phone
Silver Version
Titanium Black Version
(for Ukraine)
Telephone Equipment
ORDER NO. KM40603007CE
 1 
ABOUT LEAD FREE SOLDER (PbF: Pb free) 
4
 1.1. 
Suggested PbF Solder 
4
 1.2. 
How to recognize that Pb Free solder is used 
5
 2 
FOR SERVICE TECHNICIANS 
5
 3 
CAUTION 
5
 4 
OPERATING INSTRUCTIONS 
6
 4.1. 
Battery 
6
 4.2. 
Location of Controls 
7
 4.3. 
Connections 
8
 4.4. 
Guide to Settings 
9
 4.5. 
For Service Hint 
11
 5 
DISASSEMBLY INSTRUCTIONS 
12
 5.1. 
Base Unit 
12
 5.2. 
Handset 
13
 5.3. 
Charger Unit 
14
 6 
ASSEMBLY INSTRUCTIONS 
15
 6.1. 
Warning When Constructing the Base Unit 
15
 6.2. 
How to Replace the Handset LCD 
16
 7 
TROUBLESHOOTING GUIDE 
17
 7.1. 
Check Power 
18
 7.2. 
Check Battery Charge 
19
 7.3. 
Check Link 
20
 7.4. 
Check Handset Transmission 
22
 7.5. 
Check Handset Reception 
22
 7.6. 
Check Caller ID 
22
 7.7. 
Bell Reception 
22
 8 
TROUBLESHOOTING BY SYMPTOM (BASE UNIT AND
CHARGER UNIT) 
23
 8.1. 
Check Point (Base Unit) 
23
 8.2. 
The Setting Method of JIG (Base Unit) 
28
 8.3. 
Adjustment Standard (Base Unit) 
30
 8.4. 
Check Point (Charger Unit) 
32
 8.5. 
Adjustment Standard (Charger Unit) 
32
 9 
TROUBLESHOOTING BY SYMPTOM (HANDSET) 
33
 9.1. 
Check Point (Handset) 
33
 9.2. 
The Setting Method of JIG (Handset) 
36
 9.3. 
Adjustment Standard (Handset) 
38
 10 THINGS TO DO AFTER REPLACING IC 
39
 10.1. Base Unit 
39
 10.2. Handset 
39
 11 RF SPECIFICATION 
40
 11.1. Base Unit 
40
 11.2. Handset 
40
 12 HOW TO CHECK THE HANDSET SPEAKER 
40
 13 FREQUENCY TABLE (MHz) 
41
 14 BLOCK DIAGRAM (BASE UNIT) 
42
 15 CIRCUIT OPERATION (BASE UNIT) 
43
 15.1. Outline 
43
 15.2. Power Supply Circuit 
44
 15.3. Telephone Line Interface 
45
 15.4. Transmitter/Receiver 
45
 15.5. Pulse Dialling 
45
 16 BLOCK DIAGRAM (HANDSET) 
46
 17 CIRCUIT OPERATION (HANDSET) 
47
 17.1. Outline 
47
 17.2. Power Supply Circuit/Reset Circuit 
47
 17.3. Charge Circuit 
47
 17.4. Battery Low/Power Down Detector 
47
 18 CIRCUIT OPERATION (CHARGER UNIT) 
48
 18.1. Power Supply Circuit 
48
 19 SIGNAL ROUTE 
49
 20 CPU DATA (BASE UNIT) 
50
 20.1. IC2 (BBIC) 
50
 21 CPU DATA (HANDSET) 
52
 21.1. IC4 (BBIC) 
52
 22 ENGINEERING MODE 
54
 22.1. Base Unit 
54
 22.2. Handset 
56
 23 EEPROM LAYOUT (BASE UNIT) 
58
 23.1. Scope 
58
 23.2. Introduction 
58
 23.3. EEPROM Layout 
58
 24 EEPROM LAYOUT (HANDSET) 
61
 24.1. Scope 
61
Note:
Because CONTENTS 4 is the extract from the Operating Instructions of this model, it is subject to change without notice. You can
download and refer to the original Operating Instructions on TSN Server for further information.
CONTENTS
 Page 
Page
2
KX-TG1107UAS / KX-TG1107U AT / KX-TG1108U AS / KX-TG1108U AT / KX-TGA110UAS / KX-TGA110UAT
 24.2. Introduction 
61
 24.3. EEPROM contents 
61
 25 HOW TO REPLACE THE FLAT PACKAGE IC 
64
 25.1. PREPARATION 
64
 25.2. FLAT PACKAGE IC REMOVAL PROCEDURE 
64
 25.3. FLAT PACKAGE IC INSTALLATION PROCEDURE 
65
 25.4. BRIDGE MODIFICATION PROCEDURE 
65
 26 CABINET AND ELECTRICAL PARTS (BASE UNIT) 
66
 27 CABINET AND ELECTRICAL PARTS (HANDSET) 
67
 28 CABINET AND ELECTRICAL PARTS (CHARGER UNIT) 
68
 29 ACCESSORIES AND PACKING MATERIALS 
69
 29.1. KX-TG1107UAS/UAT 
69
 29.2. KX-TG1108UAS/UAT 
70
 30 TERMINAL GUIDE OF THE ICs, TRANSISTORS AND DIODES
 
71
 30.1. Base Unit 
71
 30.2. Handset 
71
 30.3. Charger Unit 
71
 31 REPLACEMENT PARTS LIST 
72
 31.1. Base Unit 
72
 31.2. Handset 
73
 31.3. Charger Unit 
74
 31.4. Accessories and Packing Materials 
74
 31.5. Fixtures and Tools 
75
 32 FOR SCHEMATIC DIAGRAM 
77
 32.1. Base Unit (SCHEMATIC DIAGRAM (BASE UNIT)) 
77
 32.2. Handset (SCHEMATIC DIAGRAM (HANDSET)) 
77
 32.3. Charger Unit (SCHEMATIC DIAGRAM (CHARGER UNIT))
 
77
 33 SCHEMATIC DIAGRAM (BASE UNIT) 
78
 34 SCHEMATIC DIAGRAM (HANDSET) 
80
 35 SCHEMATIC DIAGRAM (CHARGER UNIT) 
82
 36 CIRCUIT BOARD (BASE UNIT) 
83
 36.1. Component View 
83
 36.2. Flow Solder Side View 
84
 37 CIRCUIT BOARD (HANDSET) 
85
 37.1. Component View 
85
 37.2. Flow Solder Side View 
86
 38 CIRCUIT BOARD (CHARGER UNIT) 
87
 38.1. Component View 
87
 38.2. Flow Solder Side View 
87
3
KX-TG1107UAS / KX-TG1107U AT / KX-TG1108U AS / KX-TG1108U AT / KX-TGA110UAS / KX-TGA110UAT
1 ABOUT LEAD FREE SOLDER (PbF: Pb free)
Note:
In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that
contains lead.
We will use PbF solder when discussing the lead free solder used in our manufacturing process which is made from Tin (Sn),
Silver (Ag), and Copper (Cu).
This model, and others like it, manufactured using lead free solder will have PbF stamped on the PCB. For service and repair
work we suggest using the same type of solder.
Caution
     • 
• 
• 
• PbF solder has a melting point that is 50°F ~70°F (30°C ~ 40°C) higher than Pb solder. Please use a soldering iron with
temperature control and adjust it to 700°F ± 20°F (370°C ± 10°C).
     • 
• 
• 
• Exercise care while using higher temperature soldering irons.: Do not heat the PCB for too long time in order to prevent
solder splash or damage to the PCB.
     • 
• 
• 
• PbF solder will tend to splash if it is heated much higher than its melting point, approximately 1100°F (600°C).
     • 
• 
• 
• When applying PbF solder to double layered boards, please check the component side for excess which may flow onto the
opposite side (See the figure below).
1.1. Suggested PbF Solder
There are several types of PbF solder available commercially. While this product is manufactured using Tin, Silver, and Copper
(Sn+Ag+Cu), you can also use Tin and Copper (Sn+Cu) or Tin, Zinc, and Bismuth (Sn+Zn+Bi). Please check the
manufacturer’s specific instructions for the melting points of their products and any precautions for using their product with other
materials. The following lead free (PbF) solder wire sizes are recommended for service of this product: 0.3 mm, 0.6 mm and
1.0 mm.
4
KX-TG1107UAS / KX-TG1107U AT / KX-TG1108U AS / KX-TG1108U AT / KX-TGA110UAS / KX-TGA110UAT
Page of 87
Display

Download Panasonic KX-TG1107UAS / KX-TG1107UAT / KX-TG1108UAS / KX-TG1108UAT / KX-TGA110UAS / KX-TGA110UAT Service Manual (Repair Manual)

Here you can read online and download Panasonic KX-TG1107UAS / KX-TG1107UAT / KX-TG1108UAS / KX-TG1108UAT / KX-TGA110UAS / KX-TGA110UAT Service Manual in PDF. KX-TG1107UAS / KX-TG1107UAT / KX-TG1108UAS / KX-TG1108UAT / KX-TGA110UAS / KX-TGA110UAT service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic KX-TG1107UAS / KX-TG1107UAT / KX-TG1108UAS / KX-TG1108UAT / KX-TGA110UAS / KX-TGA110UAT Telephone. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.