Read Panasonic KX-TCD965RUC Service Manual Simplified online
•|
1
•|
KX-TCD965RUC
Simplified
Digital Cordless Phone
Telephone Equipment
KX-TCD965RUC
(for Russia)
WARNING
Please use this manual together with the original Service Manual for model KX-TCD965GC order No. KM49911501C2.
This Service Manual indicates the main differences between: Original KX-TCD965GC and KX-TCD965RUC.
ORDER NO. KM40006637A2
Blue Version
•|
2
•|
KX-TCD965RUC
•¡
LOCATION OF CONTROLS (Change from original page 3)
CALLER
ID
SELECT
ERASE
ANSWER ON
GREETING
Antenna
Display
Charge Contacts
Microphone
Locator/Intercom Button
Repeat Button
Skip Button
New Message Button
Memo Button
Stop Button
Volume Buttons ,
In Use Indicator ( )
Charge Indicator ( )
CALLER ID Indicator
Button
Button
Button and Indicator
Button
SELECT
GREETING
ANSWER ON
ERASE
1
ABC
2
DEF
3
G HI
4
J KL
5
MNO
6
PQRS
7
TUV
8
0
WXYZ
9
INT'
OK
OK
PWR
RCL
F
C
Display
Power Button
PWR
Cancel Button
C
Intercom Button
I N T
Navigator Key (
,
OK
, , )
Function Button
F
Tone Button
Recall Button
RCL
Charge Contacts
Talk Button
(Model KX-TCD965RUC)
•|
3
•|
KX-TCD965RUC
•¡
CONNECTION (Change from original page 6)
(Model KX-TCD965RUC)
Plug in the AC adaptor cord and the telephone line cord to the bottom of the unit. Then
connect the cord as shown.
USE ONLY WITH Panasonic AC ADAPTOR KX-TCA11CE.
Be careful not to confuse the telephone line jack with the AC adaptor jack on the base unit. If
connected improperly, the base unit will not work and damage occur.
The AC adaptor must remain connected at all times. (It is normal for the adaptor to feel warm during
use.)
The unit will not work during a power failure. We recommend you connect a standard telephone on
the same line for power protection.
If your unit is connected to a PBX which does not support Caller ID services, you cannot access
those services.
8V
9V
Telephone
Line Cord
Line Cord
AC
Adaptor
Adaptor
Fasten the cords to prevent
them from being disconnected
them from being disconnected
.
Hooks
Telephone Line Cord
AC Adaptor
To Power Outlet
(AC 230 V, 50 Hz)
(AC 230 V, 50 Hz)
Single-Line
Telephone Jack
Telephone Jack
•|
4
•|
KX-TCD965RUC
(Model KX-TCD965RUC)
3. Send batch file “SET FREQ nn” to set the clock frequency. The default value of nn is 80. Increase the value to
increase the frequency. The clock frequency must be 10,368.000 kHz ± 0.04 kHz.
increase the frequency. The clock frequency must be 10,368.000 kHz ± 0.04 kHz.
•¡
CHECK PROCEDURE [HANDSET] (Change from original page 48)
TEST EQUIPMENT REQUIRED AND EQUIPMENT SETUP
Connect a 3.9V supply to the board J5 (+), J8 (–).
INITIAL POWER + BBIC TESTS
4. Check the 3.0V supply voltage (TP10). It must be 2.85 +/– 0.3V.
5. Connect RFCLK (TP56) to CH.1 on the scope. Send batch file RFCLK1.
6. Check if the clock waveform is 10,368.000 kHz,+/– 40Hz.
7. Send batch file “SELF TEST”. The first 4digits are FLASH ROM checksum, the next 2 digits are RAM test,
and must be 00
5. Connect RFCLK (TP56) to CH.1 on the scope. Send batch file RFCLK1.
6. Check if the clock waveform is 10,368.000 kHz,+/– 40Hz.
7. Send batch file “SELF TEST”. The first 4digits are FLASH ROM checksum, the next 2 digits are RAM test,
and must be 00
SET CLOCK FREQUENCY
1. Send batch file “RFCLK1”.
The underlined parts have been changed from the original
The underlined part has been added to the original
• Nickel Cadmium (Ni-Cd) rechargeable batteries (AAA size) are available.
When you replace the batteries, you must program the battery type selection.
When you replace the batteries, you must program the battery type selection.
•¡
Battery Information (Change from original page 7)
•¡
•¡
•¡
•¡
•¡
ACCESSORIES AND PACKING MATERIALS (Change from original page 62)
P5
Addition