KX-TCD961GB - Panasonic Telephone Service Manual (repair manual). Page 42

Read Panasonic KX-TCD961GB Service Manual online

|
44
|
KX-TCD961GB
Item(2)
  1. Connect the serial link to test computer for J6 (serial data) and J8 (GND).
  2. Connect a 3.9V supply to the handset.
  3. Press the “power on” button.
  4. Set the battery voltage to 4.6V at J1 and J2.
  5. Send batch file “READBATT.BAT”. The returned hex value is M2.
  6. Send batch file “WRTBATT.BAT M2”.
  7. Set the battery voltage to 3.46V at TP87.
  8. Send batch file “READBATT.BAT”. The returned hex value is M1.
  9. Send batch file “WRTBATT.BAT M1”.
10. Calculate the low value 2 level:
11. Send “WRTBATT.BAT M3”.
ADJUSTMENT (HANDSET)
Adjustment objectives
Tools required for adjustments
   Frequency counter
   Power supply unit (DC 3V~5V, 1A)
   Personal computer
   Serial communication tool
   Test software (batch files)
Item(1)
  1. Connect the serial link to test computer to J6 (serial data) and J8 (GND).
  2. Turn off power for the base unit.
  3. Input a 3.9V supply to the handset J5 (+) and J8 (GND).
  4. Connect the frequency counter to TP56 and J8 (GND).
  5. Connect a frequency counter between TP6 (SCLK) and J8 (GND).
  6. Press the “power on” button.
  7. Send batch file “FIXFREQ.BAT”.
  8. Use batch file “SETFREQ.BAT” to set the clock frequency. The default value is 80. Increase the value to increase
      the frequency and vice-versa. The clock frequency must be 10,368.000 kHz ± 0.02 kHz.
Adjustment item
Symptom
Synchronization with the base unit is lost immediately.
No link is established.
Remedy
Perform the adjustments described in item(1).
Clock frequency
The communication (standby) times is short.
The low battery display period is too long or too short.
Perform the adjustments described in item(2).
Low battery
M3 Dec =
M1 Dec – (M2 Dec – M1 Dec) X 0.1
4.66 – 3.46
Page of 66
Display