12 CHECK PROCEDURE (BASE UNIT)
12.1. TEST EQUIPMENT REQUIRED AND EQUIPMENT SETUP
12.2. INITIAL POWER + BBIC TESTS
 1. Turn on the 10V supply.
 2. Check for approx. 75 mA current on the 10V supply.
 3. Check the 4V supply voltage (TP91). It must be 4.2 ± 0.2V.
 4. Check the 3.1V supply voltage (TP95). It must be 3.1 ± 0.2V.
 5. Check the 6V supply voltage (TP109). It must be 6.4 ± 0.3V.
 6. Connect SCLK (TP148) to CH.1 on the scope.
 7. Check if the clock waveform is 3,456 kHz.
 8. Send batch file “SELF TEST”.
12.3. SET THE CLOCK FREQUENCY
 1. Transfer SCLK (TP148) to the frequency counter.
 2. Send batch file “SETFREQ nn” to set the clock frequency. The default value of nn is 80. Increase the value to increase the
frequency and vice-versa. The clock frequency must be 3,456 kHz (± 0.007 kHz).
12.4. QUICK Tx CHECK
 1. Set the CMD60 to MODULE TEST.
 2. Send batch file “RF-I”.
 3. Confidence check of Power (NTP): it must be +20 to +25 dBm.