KX-TCA285RU - Panasonic Telephone Service Manual (repair manual). Page 45

Read Panasonic KX-TCA285RU Service Manual online

45
KX-TCA285RU
11.2. Adjustment (Handset)
This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the measurement in
Troubleshooting Guide
11.2.1.
Equipment Required
• Digital multi-meter (DMM): it must be able to measure voltage and current.
• Oscilloscope.
• Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm)
• DECT tester: Rohde & Schwarz, CTS 60 is recommended.
11.2.2.
The Setting Method of JIG
<Preparation>
• Serial JIG cable: PSZZ1TD7896M
• PC which has “Flash Program.exe”
11.2.3.
Connections (Handset)
1. Connect the DC Power or Battery to BATT+ and BATT-.
2. Connect the JIG cable  to CN100.
R401
DOUT3V
R402
R403
R210
R216 R217
R218
R219
R602
R603
R605
R606
R607
R220
3.0V
CHG+
MIC
-
MIC+
CHG
-
GND_J
C201
C202
C203
C204
TH
RA101
C206
C207
C210
RA301
C211
BT3.0V
C213
C215
C216
C217
C218
C601
C223
C226
SPM
SPP
D203
TCK
URX
TDI
TDO
IC201
IC202
IC203
IC205
IC401
UTX
Q521
Q523
MIC+
Q524
MIC-
Q527
Q528
IC601
Q540
R104
R106
R304
R305
R306
CN100
VIB
BLK
R505
R506
R507
R120
R509
L2
R510
R511
R514
RTCK
R517
CN500
C101
C102
C104
C105
C106
C107
C108
C109
C301 C302
C110
C111
C112
C113
C114
C115
C116
C117
C118
C119
VDDC
TMS
R540
C
RA401
R541
C311
R542
C312
R543
C313
F201
OF1
OF2
D300
D301
BATT
BATT+
2.5A
BATT-
L200
L201
Q601
Q602
IC100
IC101
IC102
CKM
D540
C11
R201
R204
GND
R205
R206
R207
R208
R209
C331
R122
R321
R123
R124 R121
R125
A
RED
DC3.8䌶 Power
or Battery
1
2
* : COM port names may vary 
    depending on what your PC calls it .
Page of 72
Display

Click on the first or last page to see other KX-TCA285RU service manuals if exist.