Read Panasonic AW-PH650N / AW-PH650L Service Manual online
INF-6
4. COM port selection
On the Communication Port screen, select the port
to which the program writing cable is connected
forSelect Port item, and click the “Next”.
to which the program writing cable is connected
forSelect Port item, and click the “Next”.
5. Device setting
On the Device Settings screen, enter “16.0000” Mhz
into the CPU crystal frequency item, and click the
“Next”.
into the CPU crystal frequency item, and click the
“Next”.
6. Connection setting
On the Connection Type screen, select “BOOT Mode”
for Select Connection item. Enter “19200” into the Rec-
ommended Speeds item, and click the “Next”.
for Select Connection item. Enter “19200” into the Rec-
ommended Speeds item, and click the “Next”.
7. Option setting
On the Programming Option screen, Select “Auto-
matic” for Protection item, and “Advanced” for Mes-
saging item, and then complete the settings.
matic” for Protection item, and “Advanced” for Mes-
saging item, and then complete the settings.
8. Cable connection
Connect the program writing cable to the connector
“P305” of HOUSING board and the “PC (RS232C)”,
and then turn on the power.
“P305” of HOUSING board and the “PC (RS232C)”,
and then turn on the power.
9. Program software selection
On the Start screen, check the “User Area” option of
the Download File Area item, and select the program
to be written for User Area item of the Download File
in the File Selection block.
(Be sure to confirm the program file name.)
the Download File Area item, and select the program
to be written for User Area item of the Download File
in the File Selection block.
(Be sure to confirm the program file name.)