Warning Situations That Are Not Recorded in the Emergency History
In case of the following errors, the applicable error code is displayed in the FDP on the front panel.
In case of the following errors, the applicable error code is displayed in the FDP on the front panel.
Table 1-3-4(b)
E-09
Pre-amp. circuit
↓
MAIN board
IC601 S
↓
MAIN board
IC601 S
Recording check
error
error
This error is identified when recording
check finds that the played FM level is
low (pin 87 of IC601 is below 0.4 V).
check finds that the played FM level is
low (pin 87 of IC601 is below 0.4 V).
E-09 is displays about
10 seconds.
The cleaner should be
activated.
10 seconds.
The cleaner should be
activated.
Video head is dirty or its service life expired.
Preamplifier circuit failure.
Preamplifier circuit failure.
E-10
Backup battery
low power error
low power error
Battery
↓
MAIN board
IC608 3
↓
MAIN board
IC608 3
This error is identified when the battery
voltage is below 2.75 V.
voltage is below 2.75 V.
E-10 is displays when
power is switched OFF.
power is switched OFF.
Battery capacity is insufficient.
Battery is not loaded.
Battery is not loaded.
E-11
Video signal input
error
error
MAIN board
IC601 p
IC601 p
MAIN board
IC601 &*
IC601 &*
This error is identified when there is no
video input at VIDEO IN jack.
video input at VIDEO IN jack.
Video signal is not supplied.
E-12
EEPROM write
error
error
This error is identified when a verification
error occurs after EEPROM write.
error occurs after EEPROM write.
E-12 is displayed when
power is switched ON.
power is switched ON.
EEPROM defect,
CPU
CPU
→ EEPROM communication line defect.
Error
Code
Code
Description
Sensors
Detection Method
Possible Causes
Operation after
Detection
E-11 is displayed when
power is switched ON.
power is switched ON.
1.3.5
Mecha check mode
This screen is used to diagnose the mechanism operation sen-
sors without using a measuring tool.
sors without using a measuring tool.
Table 1-3-5(a)
(MODE)
Previous and current modes of the VCR.
–
(ENCD)
Rotary encoder output level.
MAIN board
IC606 4 LS1
IC606 5 LS2
IC606 6 LS3
IC606 7 LS4
IC606 4 LS1
IC606 5 LS2
IC606 6 LS3
IC606 7 LS4
The H/L display varies according to the mechanism position.
(ENCD)
Display
ATOFF
OPOFF
NOCAS
EJECT
FF
REW
OPOFF
NOCAS
EJECT
FF
REW
Description
→ AUTO OFF
→ OPERATE OFF
→ NO CASSETTE
→ EJECT
→ FF
→ REW
Display
PLAY
RPLAY
STOP
STILL
S.FWD
R.REV
RPLAY
STOP
STILL
S.FWD
R.REV
Description
→ PLAY
→ REVERSE
→ STOP
→ STILL
→ SHUTTLE FWD
→ SHUTTLE REV
(REF.)
Normal output level of rotary encoder.
(SAFE)
REC SAFETY switch status.
MAIN board
IC606 %
IC606 %
–
ON:
OFF:
When a cassette with a broken safety tab is inserted or during cassette
loading/ejection.
When a cassette with integral safety tab is inserted or when no cassette
is loaded.
loading/ejection.
When a cassette with integral safety tab is inserted or when no cassette
is loaded.
ON:
OFF:
OFF:
When a cassette is inserted.
When no cassette is loaded or during cassette loading/ejection.
When no cassette is loaded or during cassette loading/ejection.
(CASS)
Cassette switch status.
MAIN board
IC606 $
IC606 $
(BGIN)
Tape begin sensor status.
MAIN board
IC601 U
IC601 U
ON:
OFF:
OFF:
When the leader tape is detected or when no cassette is loaded.
When the magnetic tape section is detected.
When the magnetic tape section is detected.
ON:
OFF:
OFF:
When the leader tape is detected or when no cassette is loaded.
When the magnetic tape section is detected.
When the magnetic tape section is detected.
ON:
OFF:
OFF:
When the capstan motor is rotating.
When the capstan motor is stopped.
When the capstan motor is stopped.
FWD:
REV:
REV:
During forward rotation.
During reverse rotation.
During reverse rotation.
(END)
Tape end sensor status.
MAIN board
IC601 I
IC601 I
(CAPN)
Capstan motor operation mode.
MAIN board
TP617
TP617
(F/R)
Capstan motor rotation direction.
MAIN board
TP610
TP610
(SPFG)
SP reel FG sensor status.
MAIN board
IC601 1
IC601 1
H/L are alternated when the reel disk rotates.
The alternation rate increases when the rotation speed increases.
The alternation rate increases when the rotation speed increases.
If the tape speed during FF or REW operation does not decelerate near the end
or the beginning of the tape,the detection by one of these sensors may be
defective.
In this case, check if the reel FG and capstan FG signals are supplied normally
to the CPU.
or the beginning of the tape,the detection by one of these sensors may be
defective.
In this case, check if the reel FG and capstan FG signals are supplied normally
to the CPU.
(TUFG)
TU reel FG sensor status.
MAIN board
IC601 2
IC601 2
–
–
–
(SP. D)
SP reel winding diameter (in mm).
(TU. D)
TU reel winding diameter (in mm).
(REMN)
Current remaining tape (in min.) assuming that
the tape speed is SP.
the tape speed is SP.
Item
Displayed Information
Input Pin
Check Method
H H L L
LS4
LS3
LS2
LS1
LS3
LS2
LS1
H H L L
LS4
LS3
LS2
LS1
LS3
LS2
LS1
(REF.)
(MODE) EJECT
(ENCD) HHLL
(SAFE) ON
(BGIN) ON
(ENCD) HHLL
(SAFE) ON
(BGIN) ON
(CAPN) OFF
(SPFG) L
(SP. D) 070
(REMN) 000
(SPFG) L
(SP. D) 070
(REMN) 000
[MECHA CHECK MODE]
→ NOCAS
(REF.) HHLL
(CASS) OFF
(END) ON
(REF.) HHLL
(CASS) OFF
(END) ON
(F/R) FWD
(TUFG) H
(TU. D) 070
(TUFG) H
(TU. D) 070