INF-18 
Focus control voltage (V) 
FOCUS 
7-2. FOCUS/IRIS REMOTE
 
 
Please refer to below indicated specification, When external remote is checked. 
 
Terminal (refer to figure A) 
Contents 
A GND 
B FOCUS 
control 
input 
IRIS control input 
IRIS(AUTO/MANU) switch input 
 
Equivalent circuit of FOCUS/IRIS REMOTE jack 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure C 
 
7-2-1. Focus control input 
With the voltage to input to the B terminal, the focus is changes. As for the relation between the focus control 
voltage and the focus, it is as shown in the following. 
 
Relation between the focus control voltage and focus 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure D 
 
When terminal B is open, the focus remote control becomes invalid. 
 
0 0.5 1.0 1.5 2.0 
0Ω 10kΩ 20kΩ 
NEAR 
FAR 
NOTE: 
The control voltage and the 
focus, which are shown below
 
are a reference value. Because 
there is a little difference, see 
as the reference data. 
4-pole / 3.5mm diameter 