INF-12 
5-2. DIAGNOSTIC MENU (VCR mode)
 
5-2-1. How to display the Error Rate. 
This unit can be displayed Error Rate and it shows the playing condition of the VCR. 
In case of the error rate is displayed, BER DISPLAY and SAMPLE SPEED mode is select on DIAGNOSTIC menu. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
How to confirm the Error rate. 
1. Select the TOTAL in item of BER DISPLAY. 
2. Record the color bar signal on LP mode and playback the recorded portion. Confirm that the number of bar on 
display within 10 bars or less. The less bars displayed the better the error rate. 
TOT 
When selecting TOTAL in BER DISPLAY 
mode, it is displayed “TOT” and if select 
VIDEO, it is displayed    “VID” and if select 
AUDIO, it is displayed “AUD”. 
TOT 
CH1 
CH2 
The color of the bar 
In case of green display: Error rate is good 
In case of red display: Error rate is bad 
CH1 
CH2 
Select SLOW or FAST by OPERATION LEVER 
and press SET(STILL) of OPERATION LEVER. 
Factory default setting is “SLOW”. 
DIAGNOSTIC MENU 
 
BER DISPLAY                            OFF 
SAMPLE SPEED           SLOW 
DIF INFO                                      OFF 
CYLINDER                10000H 
TAPE RUN                10000H 
THREADING               10000T 
 
 
 
PUSH MENU TO EXIT 
DIAGNOSTIC MENU 
 
BER DISPLAY                            TOTAL 
SAMPLE SPEED            SLOW 
DIF INFO                                      OFF 
CYLINDER                10000H 
TAPE RUN                10000H 
THREADING               10000T 
 
 
 
PUSH MENU TO EXIT 
OFF 
VIDEO 
AUDIO 
TOTAL 
SLOW 
FAST 
Select the item BER DISPLAY and press
SET(STILL) of OPERATION LEVER. 
Select VIDEO, AUDIO or TOTAL by
OPERATION LEVER and press SET(STILL) of
OPERATION LEVER. 
Factory default setting is “OFF”. 
After selecting BER DISPLAY mode, move to 
item of SAMPLE SPEED by tilt the 
OPERATION LEVER in the DOWN ( 
■ 
:STOP) 
direction. 
The Audio Level Meter is change to error rate 
display, when returning to the normal screen. 
NOTE: 
The display screen is changed only in the VCR 
mode. 