ELE-22 
6-5. White Balance Adjustment (AUTO) 
This adjustment can be adjust automatically. 
Set to CAMERA mode in camera recorder follow the message “Auto / Manually set to CAMERA mode.”, and 
then press the “Enter” key. 
<Preparation> 
1. Set the ND FILTER SW to 1/8 position. 
2. Set the camera recorder to ATW mode. 
3. Execute the ABB. 
 
6-5-1. Indoor (3100K) White Balance Adjustment (AUTO) 
1.  Aim the camera recorder at Grayscale Chart under the Halogen lamp condition (3100K, 2000Lux). 
2. Open the “Camera adjustment menu”
3. Select “7. White Balance adjustment” in the Camera adjustment menu, and then press the “Enter” key. 
4. Select “5. Indoor (3100K) WB adjustment (Auto)” in the White balance adjustment menu, and then press the 
“Enter” key. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
PRESS ENTER KEY, then adjustment
is started. 
When adjustment is finished, message
“Completed!” appeared and numerical
value is changed “00”