PT-VZ585N, PT-VW545N, PT-VX615N, PT-VZ580, PT-VW540, PT-VX610 (serv.man7) - Panasonic Projector Service Manual (repair manual). Page 88

Read Panasonic PT-VZ585N / PT-VW545N / PT-VX615N / PT-VZ580 / PT-VW540 / PT-VX610 (serv.man7) Service Manual online

ADJ-6
SECTION 3 ADJUSTMENTS
<VZ585N/VW545N/VX615N/VZ580/VW540/VX610>
1. 3. Adjusted data transfer
1. 3. 1. Equipment to be used
1. Computer : Use it for the transfer of backup data.
2. Communication cable : D-sub 9pin (male/female RS-232C straight)
3. Service Software : "ServiceVZ580.exe" is downloaded from the projector service homepage.
1. 3. 2. Connection preparations
1.  Connect the serial terminals between the projector and the PC by 
using a communication cable.
1. 3. 3.  Backup the data (before board replacing)
1. Set the projector to "Normal-Standby" mode (ON(G)/STANDBY(R) indicator is blinking in red).
2. Start up the service software with a PC.
3. Select language and click the [OK] button.
4. 1) Choose the available serial port number on your PC.
  2) Click the [Data] button.
5. 1) Click the [ Reception ] button of Micom data.
  2) Select the save place and the data is transmitted after click the [ Save(S) ] button.
  3) When the progress bar reaches the right-side end, the save of data is completion.
  4) Save the Gamma data/Uniformity data in the same procedure of 1-3.
:   PT-VZ580
k
j
/ Uniformity data
PT-VZ580
AB1234567
j
Data type
File name
Micom Data
M_Data.dat
Gamma / uniformity Data
G_Data.dat
k
Projector serial no.:Transmit it 
with the Micon data.
Projector SERIAL IN
Communication cable (straight)
Computer
D-Sub 9P
(male)
D-Sub 9p (female)
Page of 100