Maintenance
n Resetting the filter counter
After replacing the air filter units, be sure to reset the filter 
counter.
1) Press st to select [Filter counter reset].
2) Press the <ENTER> button. 
   [Filter  counter  Reset?]  appears.  Select  Yes  to  con-
tinue. Another confirmation dialog box appears, select 
Yes to reset the Filter counter.
Attention
•  Turn off the power before you replace the air filter unit.
•  When  attaching  the  air  filter  unit,  make  sure  that  the 
projector is stable, and work in an environment that is 
safe, even in the event of the air filter unit dropping.
•  Do not operate the projector with the filters removed. 
Dust may accumulate on the optical elements degrad-
ing picture quality.
•  Do not put anything into the air vents. Doing so may 
result in malfunction of the projector.
•  Do not wash the filters with water or any other liquid 
matter. Otherwise the filters may be damaged.
n Attaching the lens cap
When moving this projector or while not using it over an extended period of time, attach the lens cap.
To prevent loss for the lens cap, please according to the following procedures, attach the lens cap  with the string of 
accessories. 
Thread the thinner end of the string through 
1 1 
 
the hole on the lens cap.
Thread the other end of the string through  
2 1 
the hole on the bottom of the projector. 
Lens cap
String
n Replacement of the air filter unit (back)
1) Remove the air filter cover.
  • Open the air filter cover in the direction of the arrow in 
  the figure and remove it.
2) Remove the air filter unit.
  • Hold the knob of the air filter unit and pull out in
 
the direction of the arrow.
  •  After removing the air filter unit, remove large
 
foreign objects and dust from the air filter
compartment and the projector’s air intake port
 
if there are any.
3) Insert the new air filter unit.
  •  Hold the air filter unit that the knob is outside of
 
the projector, perform Step 2) in the reverse order.
•  Do not press the filter part when push into the
projector at last
4) Install the air filter cover.
  • Make sure that the air filter cover is closed tightly
Air filter cover (back)
Air filter unit 
(
back
)
Knob
Page of 127