PT-TW370, PT-TX430, PT-TX340 - Panasonic Projector Service Manual (repair manual). Page 55

Read Panasonic PT-TW370 / PT-TX430 / PT-TX340 Service Manual online

ADJ-7
SECTION 3 ADJUSTMENTS
<TW370/TX430/TX340>
3. 4. Service adjustment data 
Group/
item Item Name
Function
Initial
Range Note
Group 
102
Option 
0 Offset
Offset (unit 1/64 degree) indicates
0
-1056 ~ 
1056
1 Offset Switch
"0: Offset indicates (normal)  
1: Offset indicates (when the calibration is 
wrong)"
0
0-1
2 Debug Mode
0: none
0
0-1
3 Service Calibration
1: angle (0.5 degree), AD value (1/1000V) 
indicates, RS232C output
0
0-10
4 Lock Count
"If in No4 value, enters the No4 threshold 
value without keystone offset correction. "
5
1-255
5 Delta Vert Result
"If in No4 value, enters the No5 threshold 
value without keystone offset correction. "
64
1-255
6 Angle 1 Count
No6 value x No7 value = calculation number
1
1-10
7 Angle 2 Count
No6 value x No7 value = calculation number
5
1-10
8 Blind Sector 1
"Blind sector 1 (unit 1/64 degree)  
from 0 degree center projector incline and 
convert the threshold to 0 degree."
160
0-1024
9 Blind Sector 2
"Blind sector 2 (unit 1/64 degree) exceeds 
blind sector 1. Change it to No10 value in 
the threshold value (blind sector 2 + blind 
sector 1)"
32
0-1024
10 Blind Sector Bias
"Change the value when the bias  
(unit 1/64 degree) blind sector 2 (No9) is 
included in the blind sector. "
61
0-1024
Group 
200
Option
1 Baud rate setting
0: 19200 bps, 1: 9600 bps
0
0-1
RS232C baud rate change
30 Lamp life test enable
0:Disable 1:Enable, lamp service life test 
only
0
0-1
31 Lamp On time (for life test)
Startup time (minute) setting
2
1-720
32 Lamp Off time (for life test)
Off time (minute) setting
2
1-720
61 Remote control code 
switching
data=0 indicates panasonic format, data=1 
indicates sanyo format
0
0-1
80 Shipping and destination
0=worldwide, 1=JPN, 2: Education 3: 
Business
0
0-4
81 Capture
0: Disable 1: Enable
1
0-1
Group 
220
Error Log
(See Error Log section for the details)
0 Latest Error Log
0
:
0
49 fiftieth Error Log
0
50 Reset Error log
Set 10 to clear the error logs.
Group 
290
 L/R Panel
0  Panel Type Indication
0: L Panel, 20: R Panel
0
0-20
1 Setup Panel Type 
 0 Set when L Type Optical Block is used.
 20 Set when R Type Optical Block used.
10
0-20
Page of 68
Display