<TW351R>
Terminals
<COMPUTER 1
IN>
1 (High-density D-sub 15 pin female)
[RGB signal]
0.7 V [p-p] 75 Ω
HD/SYNC TTL high impedance, automatic positive/negative polarity compatible
VD TTL high impedance, automatic positive/negative polarity compatible
(HD/SYNC and VD do not support 3 value SYNC.)
[YP
B
P
R
signal] Y: 1.0 V [p-p] including synchronization signal, PBPR: 0.7 V [p-p] 75 Ω
[Y/C signal]
Y: 1.0 V [p-p] C: 0.286 V [p-p] 75 Ω S1 signal compatible
<COMPUTER 2
IN>
1 (High-density D-sub 15 pin female)
[RGB signal]
0.7 V [p-p] 75 Ω
HD/SYNC TTL high impedance, automatic positive/negative polarity compatible
VD TTL high impedance, automatic positive/negative polarity compatible
(HD/SYNC and VD do not support 3 value SYNC.)
<MONITOR
OUT>
1 (High-density D-sub 15 pin female)
[RGB signal]
0.7 V [p-p] 75 Ω
HD/SYNC TTL high impedance, positive/negative polarity compatible
VD TTL high impedance, positive/negative polarity compatible
<VIDEO IN>
1 (Pin jack 1.0 V [p-p] 75 Ω)
<HDMI IN>
1 (HDMI 19 pin, HDCP and Deep color compatible)
Audio signals: Linear PCM (Sampling frequency: 48 kHz/44.1 kHz/32 kHz)
<AUDIO IN>
1 (M3 stereo mini jack, 0.5 V [rms], input impedance 22 kΩ and more)
1 (Pin jack x 2 (L-R), 0.5 V [rms], input impedance 22 kΩ and more)
<VARIABLE
AUDIO OUT>
1 (M3 stereo mini jack, stereo monitor output compatible,
0 V [rms] to 2.0 V [rms] variable, output impedance 2.2 kΩ and less)
<USB A (VIEW-
ER/WIRELESS)>
USB connector (type A x 1, output DC 5 V, 500 mA maximum)
Memory Viewer / Wireless module (Model No.: ET-WML100) compatible
<USB B (DIS-
PLAY)>
USB connector (type B x 1), only for USB Display
<SERIAL IN>
1 (D-sub 9 pin, RS-232C compliant, for computer control use)
<LAN>
1 (for RJ-45 network connection, PJLink compatible, 10Base-T/100Base-TX)
<MINI USB>
1 (Mini USB connector for interactive function)
Power cable length
3.0 m (118-3/32")
Cabinet
Molded plastic
Dimensions
Width: 335 mm (13-3/16")
Height: 134.1 mm (5-9/32") (when adjustable feet shortened)
Depth: 329 mm (12-15/16")
Weight
Approx.3.9 kg (8.60 lbs.)
*4
Noise level
*5
When set to [ (Normal)] in [Lamp control] : 37 dB
When set to [ (Eco 1)] in [Lamp control] : 33 dB
When set to [ (Eco 2)] in [Lamp control] : 28 dB
Operating
environment
Operating
environment
temperature *6
5 °C (41 °F) to 40 °C (104 °F) (Elevation: below 1 400 m (4 593'); [High land]: [Off])
5 °C (41 °F) to 35 °C (95 °F) (Elevation: 1 400 m (4 593') ~ 2 700 m (8 858'); [High land]: [On 1])
5 °C (41 °F) to 30 °C (86 °F) (Elevation: 2 700 m (8 858') ~ 3 000 m (9 843'); [High land]: [On 2])
Operating
environment
humidity
20 % to 80 % (no condensation)
Remote
control
Power supply
DC 3 V (AAA/R03/LR03 battery x 2)
Operating range Approx. 5 m (16'4-13/16") (when operated directly in front of receptor)
Weight
Weight
63 g (2.22 ozs.) (including batteries)
Dimensions
Width : 44 mm (1-23/32"), Length : 105 mm (4-1/8"), Height :20.5 mm (13/16")
*4 This is an average value. It may differ depending on individual product.
*5 Measurement, measuring conditions and method of notation all comply with ISO/IEC 21118:2012 international standards.
*6 [Lamp control] will be switched to [ (Eco 1)] automatically when [High land] is set to [Off] and the operating environment
temperature is 35 °C to 40 °C.[Lamp control] will be switched to [ (Eco 1)] automatically when [High land] is set to [On 1] or
[On 2] and the operating environment temperature is 30 °C to 35 °C.