Read Panasonic PT-RZ670 / PT-RW630 (serv.man8) Other Service Manuals online
SECTION 1 SERVICE INFORMATION
< RZ670/RW630 >
3. SELF CHECK
・
Self-diagnosing information Displays.
SELF CHECK
(1)-
MAIN : 1.00
(1) Main microprocessor software version
(2)-
SUB : 1.00
(2) Sub microprocessor software version
(3)-
DIGITAL LINK : 1.30.20.5
(3) DIGITAL LINK microprocessor software version
(4)-
DDP : 00.0400.00
(4) Formatter microprocessor software version
(5)-
LD : 1.00 / 1.00
(5) LD driver main software version (LD1/LD2)
(6)-
LD SUB : 1.00
(6) LD driver sub software version
(7)-
EMULATE : DEFAULT
(7) Emulate setting state
(8)-
OK AIR TEMP 123/456 OK DMD TEMP 123/456
(8) Intake air temperature (Celsius/Fahrenheit)
(9)-
OK OUT TEMP 123/456 OK LD 123/456
DMD temperature (Celsius/Fahrenheit)
(10)-
OK FAN 1111 1111 1111 1
(9) Exhaust air temperature (Celsius/Fahrenheit)
(11)-
OK LD1 1111 LD2 1111
LD temperature (Celsius/Fahrenheit)
(12)-
OK PHOTO 123456/123456/123456/123456
(13)-
OK ANGLE SENSOR H -12.34/V +12.34
(14)-
OK ATM SENSOR 1234/567
(10) Fan condition (1: normal / 0:stop)
OK FAN
(11) LD units condition (1: normal / 0:stop)
OK LD1
LD2
(12) Color sensor condition (Red / Green / Blue / Yellow)
(13) Angle sensor condition (Horizontal angle / Vertical angle)
(14) Atmosphere sensor condition (hPa / Celsius)
(13) Angle sensor condition (Horizontal angle / Vertical angle)
(14) Atmosphere sensor condition (hPa / Celsius)
4. AUTO INDEX CALIBRATION
・
When replaced the phosphor wheel and trimming wheel, perform automatic adjustment of each wheel rotational phase.
* Please refer to SECTION 3 (Adjustments) for the procedure.
5. PW1 INDEX
6. PW2 INDEX
7. CW INDEX
6. PW2 INDEX
7. CW INDEX
8. POWER OFF MESSAGE
・
Operation setting of shutter at turning off the projector
- SHUTTER KEEP: When pushing the standby key while the shutter mode is on, the projector keeps the shutter
mode on and sets into standby mode.
- SHUTTER OPEN: When pushing the standby key while the shutter mode is on, the projector opens the shutter
and displays the "Power OFF confirmation message". (Default setting)
9. ERROR OSD
・
The screen display setting of the light source error. (for rear projection)
- ON: "LD1/LD2 error message" is displayed on OSD.
- OFF: Does not display the "LD1/LD2 error message" in OSD. (Default setting)
- OFF: Does not display the "LD1/LD2 error message" in OSD. (Default setting)
10. MODEL
・
Set this when the A-P.C.Board is replaced.
* If you can copy EEPROM data from the old A-P.C.Board, this setting is unnecessary.
* This model setting is changed after turn power restart.
* This model setting is changed after turn power restart.
L
D
1-1
L
D
1-2
L
D
1-3
L
D
1-4
L
D
2-1
L
D
2-2
L
D
2-3
L
D
2-4
Make the rotation phase adjustment of the wheels individually.
(Please do not change the setting, usually.)
・
1 1 1 1 1 1 1 1 1 1 1 1 1
RADIATOR3
PW1
PW2
POWER
LD DRIVER
EXHAUST3
DMD
EXHAUST1
EXHAUST2
RADIATOR2
RADIATOR1
PUMP1
PUMP2
1 1 1 1
1 1 1 1
* When [OK] item is abnormal last time and shuts it down, font of [OK] becomes red.