PT-RZ670, PT-RW630 (serv.man8) - Panasonic Projector Other Service Manuals (repair manual). Page 28

Read Panasonic PT-RZ670 / PT-RW630 (serv.man8) Other Service Manuals online

SECTION 1  SERVICE  INFORMATION
< RZ670/RW630 >
Bit
Self-test indication
Details
Probable cause
Related P.C.Board
40
00000100 00000000
Unused
-
41
00000200 00000000
Unused
-
42
00000400 00000000
FE1/(F50) Intake fan 3 error /(Warning)
DG、RT
43
00000800 00000000
FE2/(F51) Phosphor wheel 1 fan error /(Warning)
DG、RB
44
00001000 00000000
FE3/(F52) Phosphor wheel 2 fan error /(Warning)
DG、RT
45
00002000 00000000
FE4/(F53) Power intake fan error /(Warning)
DG,R
46
00004000 00000000
FE5/(F54) Drive fan error /(Warning)
DG
47
00008000 00000000
FE6/(F55) Power exhaust fan error /(Warning)
DG
48
00010000 00000000
FE7/(F56) DMD fan error /(Warning)
DG
49
00020000 00000000
FE8/(F57) Exhaust fan 1 error /(Warning)
DG,BR
50
00040000 00000000
FE9/(F58) Exhaust fan 2 error /(Warning)
DG
51
00080000 00000000
FF0/(F59) Intake fan 2 error /(Warning)
DG,RM
52
00100000 00000000
FF1/(F70) Intake fan 1 error /(Warning)
DG,RM
53
00200000 00000000
Unused
-
54
00400000 00000000
Unused
-
55
00800000 00000000
Unused
-
56
01000000 00000000
Unused
-
57
02000000 00000000
Unused
-
58
04000000 00000000
Unused
-
59
08000000 00000000
Unused
-
60
10000000 00000000
Unused
-
61
20000000 00000000
FJ0/(F00) Liquid cooling pump1 error /(warning)
DG、BR
62
40000000 00000000
FJ1/(F01) Liquid cooling pump2 error /(warning)
DG、BR
63
80000000 00000000
Unused
-
64
00000000 00000001
Unused
-
65
00000000 00000002
Unused
-
66
00000000 00000004
Unused
-
67
00000000 00000008
Unused
-
68
00000000 00000010
U25
LD1 temperature error
D,DR
69
00000000 00000020
U26
LD2 temperature error
A,DG,RT
70
00000000 00000040
Unused
-
71
00000000 00000080
Unused
-
72
00000000 00000100
H14
LD1 temperature sensor not present
LD1 temperature sensor has breaking
of wire, or connector (DR6) is
disconnected
DR
73
00000000 00000200
H15
LD2 temperature sensor not present
LD2 temperature sensor has breaking
of wire, or connector (RT12/RT1) is
disconnected
A,DG,RT
74
00000000 00000400
Unused
-
75
00000000 00000800
Unused
-
76
00000000 00001000
U16
LD1 temperature warning
D,DR
77
00000000 00002000
U17
LD2 temperature warning
A,DG,RT
78
00000000 00004000
Unused
-
79
00000000 00008000
Unused
-
80
00000000 00010000
F91
FPGA1 configuration error
A
81
00000000 00020000
F92
FPGA2 configuration error
A,DG
82
00000000 00040000
F90
FPGA configuration error
A,DG
83
00000000 00080000
Unused
-
84
00000000 00100000
Unused
-
Error code (hex)
LOWE
R
Fan or fan drive circuit is failure
Fan replacement time.
Pump or pump drive circuit is failure
Liquid cooling unit replacement time
U
PPER
Environment temperature is too high
Radiator clogging
Liquid cooling unit is failure
High altitude mode is mis select
Environment temperature is too high
Radiator clogging
Liquid cooling unit is failure
High altitude mode is mis select
Signal processing circuit failure
INF - 28
Page of 42
Display

Click on the first or last page to see other PT-RZ670 / PT-RW630 (serv.man8) service manuals if exist.