SECTION 3  ADJUSTMENTS
< RZ670/RW630 >
3. Index adjustment pattern is projected automatically, automatic adjustment is started.
4. It is adjustment completion if displayed with "AUTO INDEX CALIBRATION COMPLETE".
[If an error message is displayed]
・ Example
  PW1  Sensor value is wrong
  PW2  Sensor value is wrong
  CW   Sensor value is wrong
  PW1  Adjustment was failed
 Calculation error of phosphor wheel 1. Replace the phosphor wheel 1, please readjustment. 
  PW2  Adjustment was failed
 Calculation error of phosphor wheel 2. Replace the phosphor wheel 2, please readjustment. 
  CW   Adjustment was failed
 Calculation error of trimming wheel. Replace the trimming wheel, please readjustment. 
  1. 4. EEPROM data transfer
The EEPROM data transfer via LAN terminal or serial terminal.
    1. 4. 1. Equipment to be used
1. Computer : Use it for the transfer of backup data.
2. Communication cable
  D-sub 9pin (male/female RS-232C straight)
  LAN cable. (When connecting directly, use a cross cable)
3. Service Software : [DataLogBackup.exe] Please download the service software from the projector service Web (PASS).
    1. 4. 2. Connection preparations
1. Check the settings of the projector.
1) The [INPUT SELECT] of sub menu [RS-232C] must be set according to the connection method.
2) The [EMULATE] of sub menu [RS-232C], is select to [DEFAULT]. (in service mode)
3) Check the RS-232C settings (ID, Baudrate  and Parity) and take a note.
1) The [DIGITAL LINK MODE] of sub menu [NETWORK], is select to [AUTO] or [ETHERNET].
2) Check the network IP address of the projector and take a note.
3) Set the IP address of computer to approximate value of projector IP address.
[Note]
・If you have changed the each menu settings, please return settings of the original (customers) after work.
・Set up your computer not to standby or shutdown.
Serial terminal connection
LAN terminal connection
Error message
Measure
 Measured value of color sensor is abnormal.
 Replace the color sensor, please readjustment.
Serial terminal connection
LAN terminal connection
ADJ - 4
Page of 14