5. 2. Shutdown system
• This projector provides the shutdown function to set into the standby mode immediately for product safety when the projector
has the fan operation error or lightning error.
Indicator status
Self-test
display
Shutdown detection
Probable cause
OSD warning, others
Not lighting or flashing
–
Power circuit (P-P.C.Board)
Fuse (F9100) : Rated 10A
Blown out of fuse
(with another reason)
–
STANDBY/ON blinks
3 times in red
F90/F91/F92 FPGA config error or communication
error
Failure on signal processing part
–
–
Main firmware boot error
Main microprocessor rewrite error
–
F97/F98
Formatter initializing error (A97)
Formatter status error (A98)
A-P.C.Board failure.
–
FH0/FH1
Phosphor wheel rotation speed
Detect by Main CPU (FH0) or FPGA
(FH1)
a
a
Under 60Hz
* Shutdown if the 60 msec (3 times by
20 msec) NG is detected before turn-
ing on the light at power-on.
Connector contact failure
Phosphor wheel or drive circuit failure
C2-P.C.Board failure
–
F85/F86
Color wheel rotation speed
Detect by Main CPU (F85) or FPGA (F86)
a
a
Under 60Hz
* Shutdown if the 60 msec (3 times by
20 msec) NG is detected before turn-
ing on the light at power-on.
Connector contact failure
Color wheel or drive circuit failure
C1-P.C.Board failure
F99
[RZ575T only]
AC input voltage
a
a
Over AC 170V±10V
Rated voltage NG
–
STANDBY/ON lights
in red
TEMP lights
H11
Intake air temperature sensor
a Lower than -20ºC
Intake air temperature sensor error
Connector contact failure or disconnect
–
H12
Optical module temperature sensor
a Lower than -20ºC
Optical module temperature sensor error
(FM-P.C.Bosrd)
–
H13
Exhaust air temperature sensor
a Lower than -20ºC
Exhaust air temperature sensor error
Connector contact failure or disconnect
–
H14/H16
LD1/2 units temperature sensor (H14)
LD3/4 units temperature sensor (H16)
a Lower than -20ºC
Temperature sensor error or disconnect
LD1/2 : Connector BR11
LD3/4 : Connector BR10
–
TEMP blinks 3 times
(In Warning: TEMP lights)
FE1~FE7
(F50~F56)
Each FAN sense signal undetectable
a Fan rotation signal is not detected
for more than 5 sec.
Each FAN sense signal
a Fan rotation is lower than 70% of
target for more than 5 seconds
Connector disconnection
Fan control circuit failure
Fan rotation error, end of life
If one of the fans stops,
the projector does not
shut down and reduces
the LD output power until
turning off.
If more than two fans have
an error, the projector shut
down.
(Warning) Each FAN sense signal
a Fan rotation is lower than 80% of
target for more than 5 seconds
TEMP blinks 2 times
(In Warning: TEMP lights)
U21
(U11)
Intake air temperature sensor
a More than 48ºC *1
Abnormal intake air temperature
External air temperature is high
Ventilation holes are blocked
"TEMPERATURE
WARNING"
U22
(U12)
Optical module temperature sensor
a More than 75ºC *1
Abnormal optical module temperature
External air temperature is high
Ventilation holes are blocked
"TEMPERATURE
WARNING"
U23
(U13)
Exhaust module temperature sensor
a More than 65ºC *1
Abnormal exhaust air temperature
External air temperature is high
Ventilation holes are blocked
"TEMPERATURE
WARNING"
U24
(U14)
Optical module temperature sensor
a Lower than 8 ºC for more than 5
min, after power on.
Operating environment temperature is
too low.
–
U25/U27
(U16/U18)
LD1/2 units temperature sensor (U25)
LD3/4 units temperature sensor (U27)
a More than 80ºC *1
Abnormal LD units temperature
External air temperature is high
Ventilation holes are blocked
"TEMPERATURE
WARNING"