ADJ-14
SECTION 3 ADJUSTMENTS
<RZ31K/RS30K>
3. Select [Setting] of [Option] menu, then select connection method and enter the setting information of the projector.
items
Default value
SERIAL
Port
–
Baud Rate
9600bps
Parity
None
LAN
IP Address
192.168.0.8
Username
admin1
Password
panasonic
Command Port
1024
Serial terminal connection
• Select [SERIAL] menu and set up the Serial Port, Baudrate and Parity of the PC.
LAN terminal connection
• Select [LAN] menu and set up the IP address, Username, Password and Command Port of the projector.
[Note] • If the Username and Password has been changed, please select serial terminal connection.
4. The status and runtime of each LD unit will be displayed by clicking the [ Get Information ] button.
[Display example] The open failure occurs on the LD1(B)-3.
When the open failure occurred, the text
characters becomes red.
In addition, "NG" is displayed on status.