Read Panasonic PT-MZ770 / PT-MW730 (serv.man3) Service Manual online
INF-13
SECTION 1 SERVICE INFORMATION
<MZ770/MW730>
SELF CHECK
1/3
MODEL : PT-MZ770
SERIAL NO. : SW12345678
---------- VERSION --------------
MAIN : 1.00.00
SUB : 1.00.00
NETWORK : 1.00
DIGITAL LINK : 1.30.90.c
FPGA : 10.00
LD : 1.000
EMULATE : DEFAULT
SERIAL NO. : SW12345678
---------- VERSION --------------
MAIN : 1.00.00
SUB : 1.00.00
NETWORK : 1.00
DIGITAL LINK : 1.30.90.c
FPGA : 10.00
LD : 1.000
EMULATE : DEFAULT
DEVICE CHECK : OK
①
②
②
③
④
⑤
⑥
⑦
④
⑤
⑥
⑦
⑨
⑧
CHANGE
SELF CHECK
2/3
---------- DEVICE CHECK ----------
CHANGE
OK : G-SAVED
OK : U-SAVED
OK : AIR TEMP 025/000
OK : OUT TEMP 025/000
OK : AIR FLOW 025.0/000/000.0
OK : LIGHT TEMP1 025
OK : LIGHT TEMP2 025
OK : LD 1 1 1 1
OK : OUT TEMP 025/000
OK : AIR FLOW 025.0/000/000.0
OK : LIGHT TEMP1 025
OK : LIGHT TEMP2 025
OK : LD 1 1 1 1
NG
: FAN 111
0
1111
OK : ATM 000.0/0.0
OK : ANGLE H +0.00/V +0.00
OK : HDCP KEY
OK : ANGLE H +0.00/V +0.00
OK : HDCP KEY
DEVICE CHECK :
NG
⑫
⑬
⑭
⑭
⑩
⑪
⑪
⑮
⑯
⑰
⑱
⑲
⑳
⑯
⑰
⑱
⑲
⑳
SELF CHECK
3/3
---------- ASIA MODEL ----------
CHANGE
CONNECTION : YES
VERSION : 01.22.333
LEVEL : 0 / 0
UNLOCK : NO
LIMIT COUNT : 0 / 0
TW STAT/DET : 0 / 0
VERSION : 01.22.333
LEVEL : 0 / 0
UNLOCK : NO
LIMIT COUNT : 0 / 0
TW STAT/DET : 0 / 0
DEVICE CHECK :
NG
㉑
㉒
㉓
㉔
㉕
㉖
㉒
㉓
㉔
㉕
㉖
2. SELF CHECK
• Self-diagnosing information Displays.
① – Model name
② – Serial no.
------------------- VERSION-----------------------------
③ – Main CPU firmware version
④ – Sub CPU firmware version
⑤ – Network firmware version
⑥ – Digital Link firmware version
⑦ – FPGA firmware version
⑧ – LD driver firmware version
⑨ – Emulate setting
------------------- DEVICE CHECK-----------------------------
⑩ – Gamma correction data (G) / Color uniformity
correction data (U)
Correction data is stored in the flash rom, if no NG.
⑪ – Intake air temperature (Celsius/Fahrenheit)
⑫ – Exhaust air temperature (Celsius/Fahrenheit)
⑬ – Air flow sensor check
(Temperature detected value(
Celsius)
/
AD conversion value/Correction value)
⑭ – LD1 temperature (Celsius)
⑮ – LD2 temperature (Celsius)
⑯ –
LD check (1: normal / 0: abnormal)
⑰ –
Fan check (1: normal / 0: abnormal)
⑱ –
Atmospheric pressure sensor check
(Sensor detected
value/Temperature detected value)
⑲ –
Angle sensor check (Horizontal angle / Vertical angle)
⑳ – HDCP key status
* The self check information below are available for Asian
model only.
㉑
– Communication status of the WL-PCB
㉒
– Firmware version of IC on the WL-PCB
㉓
– Usage environment information
Applicable country Information/Not applicable country
information
㉔
– Functional restriction setting status
YES : Function restriction has been canceled
NO : Function restriction has been enabled
㉕
– Function restriction countdown
Count of communication error/Count of environmental
error Count is decreased when an error is detected,
and become restricted with counter " 0 ". (Maximum 30)
㉖
– Taiwan region detection
[Note]
• Items
⑩
to
⑳
indicates the status of "NG" or "OK". If the "NG" indicates in red, the projector has an abnormality now. If the
"OK" indicates in red, the projector had an abnormality in the past and operates normally now.
• To clear the error status, press the [MENU] key in the SELF CHECK mode, the confirmation window will appear and select
[OK] to clear.
CLEAR ERROR INFOMATION?
OK
CANCEL
• This must be done after finishing the repair or maintenance.